AstroStart 2305A User Manual

Page 16

Advertising
background image

14

The following table shows the meaning of zone codes (number of flashes).

ZONE CODES

FLASHES

ZONE INDICATED

1

System is armed.

2

A door is/was open.

3

Hood is/was open.

4

Alarm condition is/was detected on shock sensor input.

5

Key is/was in ignition position (RUN).

6

Alarm condition is/was detected on additional sensor input.
Additional sensor monitors status of ____________________________________________________

7

Loss of power (+12V battery supply was removed).

8

Alarm status is/has been detected on pre-shock sensor input.

The codes can be displayed on the remote control by pressing (2 sec.) on the button and then simultaneously on the

and

buttons (2 sec.)

.

Indicator can show two other conditions:
CONSTANT DIM LIGHT

Indicates that alarm is permanently disarmed (see ‘Valet Mode’ on page 14).

RAPID FLASHES

Indicates that system is in rearming cycle (see ‘Semi-Passive Rearming’ and ‘Passive
Rearming’ on page 12).

SECONDARY FUNCTIONS

Anti-lock

When connected, this function prevents system from locking the doors during automatic rearming if key is in the ignition.
It can also be connected to a switch to select automatic locking as ACTIVE or INACTIVE.

Temporary Valet Mode (Alarm)

This mode is used to cancel automatic rearming for an indefinite period. You will find this mode useful when fuelling up or
working on your vehicle.

To activate Temporary Valet Mode, press

button (2 sec.) during rearming cycle (indicator light flashes rapidly). When

light stops flashing, it confirms that Temporary Valet Mode has been activated.
To cancel this mode, place ignition key in RUN position then remove it; passive rearming is reactivated when you open a
door.

You can also arm the system using the remote, which cancels Temporary Valet Mode.
VALET MODE
This mode is used to deactivate alarm permanently when you take your vehicle in for servicing for
example. It can be de/activate by the remote (see table of commands, page 6) or by the Valet switch.
See also Pager on page 5.
Valet switch activates Valet Mode or terminates alarm condition when your remote control is not
available
(lost, batteries dead, etc.).
This switch must be installed in a hidden place known only to regular users of the vehicle.
Ask your installer to tell you where it is.
T

O ACTIVATE

V

ALET

M

ODE

, place ignition key in RUN position (do not start engine) then press Valet switch (for about 3

seconds) until indicator light comes on at half-brightness for 15 seconds or less, parking lights flash four times to confirm
that mode was enabled. The indicator light comes on again when engine is stopped or when certain commands are
received to remind you that Valet Mode is active.
T

O DEACTIVATE

V

ALET

M

ODE

, place ignition key in RUN position (do not start engine) then press Valet switch (for about 3

seconds) until indicator light goes out, parking lights flash twice to confirm that mode was disabled.
Notes:
If you perform both sequences one after the other, you need to pause for 3 seconds between the two sequences.
Valet Mode is automatically deactivated when key is turned to the RUN position and/or the engine is remote started for the
tenth time. This is to prevent Valet Mode from being left on for long periods.

Advertising