Adjusting airflow direction and fan speed, Press fan speed button, Press button – Panasonic CUG95KE User Manual

Page 14

Advertising
background image

12

Auto Vertical Airflow Direction Control

Heating

When the discharge air temperature is low such as at starts of heating
operation, the air blows at horizontal level.
As the temperature rises, the hot air blows in a downwards direction.

Cooling

Soft Dry

The louver swings up and down automatically.

AUTO

AUTO FAN

FAN SPEED

WIDE/SPOT

AIR SWING

TIMER

CLOCK

1

2

3

ON

OFF

SET

CANCEL

SLEEP

MODE

AUTO

Adjusting Airflow Direction and Fan Speed

Proper adjustment of airflow direction and fan speed increases
operation effectiveness.

SPOT

WIDE

POWER

LOW

HIGH

SLEEP

TIMER

POWERFUL

POWER MONITOR

POWER

LOW

HIGH

SLEEP

TIMER

POWERFUL

POWER MONITOR

Press FAN SPEED Button

There are five stages of fan speed in addi-
tion to Auto Fan Speed.

Press

Button

There are seven positions of the horizontal airflow direction louvers
in additional to Auto Airflow Direction.

The display changes when the

button is pressed.

(The display does not show the exact directions of airflow or the
exact louver angles.)

To adjust the vertical airflow direction louvers

Auto Fan Speed Control

Heating

When the temperature of the discharge air increases,
the fan speed increases.

Cooling

Soft Dry

Changes the fan speed to generate a cool breeze. The air starts to blow out
approximately 40 seconds after the start of Cooling or Soft Dry.

Auto Horizontal Airflow Direction Control

Heating

When air temperature is low, air is sent in WIDE. When temperature goes up,
air comes out in SPOT.

Cooling

Fan

Louvers swing horizontally at a fixed speed.

Soft Dry

Louvers are fixed to WIDE.

To adjust fan speed

To adjust the horizontal airflow direction louvers

Auto Fan

Speed

Medium Fan

Speed

Display Example

COOL

AUTO FAN

COOL

h j k

Press

Button

There are five angles of vertical direction in addition to Auto Airflow
Direction.

The display changes when the

button is pressed.

(The display indicates airflow direction.)

Advertising