A.2 specifications, Input characteristics – Asus AP1600R User Manual

Page 43

Advertising
background image

ASUS AP1600R 1U Rackmount Server

43

Input Characteristics

A.2

Specifications

Output Characteristics

Over-Voltage Protection (OVP)

Input Voltage Range

Min

Nom

Max

Range 1

90V

100V

140V

Range 2

180V

240V

264V

Input Frequency Range

47 Hz to 63 Hz

Maximum Input ac Current

4.96A max. at 100Vac
2.48A max. at 200Vac
2.75A max. at 230Vac, maximum load

Inrush Current

30A cold start
30A warm start

Efficiency

72% min. at nominal input,
maximum load

Output

Load Range

Regulation

Ripple

Voltage

Min

Max

Min

Max

Max

+5V

1.0A

12.0A

-4%

+5%

50mV

p-p

+12V

1

1.5A

16.0A

-4%

+5%

120mV

p-p

+12V

2

0.5A

16.0A

-4%

+5%

120mV

p-p

-12V

0A

0.5A

-5%

+9%

120mV

p-p

+5VSB

0.1A

2.0A

-4%

+5%

50mV

p-p

+3V3

1.5A

16.0A

-3%

+5%

50mV

p-p

Output Voltage

Maximum Voltage

+5V

6.2V

+12V

14.5V

+3.3V

4.5V

+5VSB

6.5V

-12V

-14.5V

NOTE

The power supply will shut down and latch off for shorting +5V,
+12V, -12V, or +3.3V. By shorting +5VSB, the power supply can
latch down or automatically recover when the fault condition is
removed. This requires disconnecting then re-connecting the AC
power plug.

Advertising