Avalon Stoves CHELAN B-VENT 700 B-VENT User Manual

Page 10

Advertising
background image

P

AGE

10

I

NSERT

I

NSTALLATION

(C

ONT

.) -

For qualified installers only!

Re-Routing the Power Cord to the Front (continued)

2

Carefully pull on the power cord until the molex connector is exposed. Disconnect the molex
connector.

Molex Connectors

Power Cord

Wires Leading
from the Heater

3

Pry out one of the button plugs on either side of the insert (see the illustration below).

4

Open the control cover and locate the wires leading from the power cord molex connector (green,
white, and black wires). Pull these wires forward. Insert the molex connector on the power cord
through the hole exposed in step 2 and re-connect to the molex connector on the heater. Tuck any
excess wire underneath the clip on the baseplate to prevent any wires from contacting the burner
pan.

Button Plug
(found on both sides)

Remove the button
plug by prying it loose
with a screwdriver

The power cord must
be routed underneath
this clip to prevent it
from touching the
bottom of the burner
pan.

Standard
Screwdriver

5

Secure the power cord to the heater with the strain relief (see the illustration under step 1).

Advertising