Ptional, Quipment, Ontinued – Avalon Stoves CHELAN B-VENT 700 B-VENT User Manual

Page 32

Advertising
background image

P

AGE

32

O

PTIONAL

E

QUIPMENT

(C

ONTINUED

)

4

Follow the directions below to remove the natural gas orifice. Apply thread sealant to the LP orifice

(#49 - it has "49" stamped on it) and tighten in place with a 1/2" open end wrench. Replace the
spring. Slide the adjustable shutter back in place.

31

49

Push the adjustable shutter to the
left, off the orifice (be careful not
to bend the shutter linkage).

1/2" Wrench

Slide the adjustable shutter
down, away from the orifice.

Remove the spring

Use a 1/2Ó open
end wrench to
unscrew the
orifice.

The new LP orifice has
Т49У stamped on it.

The old NG orifice has
Т31У stamped on it.

Apply thread
sealant to the
new orifice
prior to
installation.

Adjustable
Shutter

Orifice

Shutter
Linkage

a

b

c

d

e

f

5

Re-attach the burner pan and burner box front to the burner pan box following the instructions in
step 3 in reverse order.

6

Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice. The propane
conversion kit includes a .016Ó (labeled LP 16) or .011Ó (labeled LP 11) pilot orifice. The .016Ó orifice is
preferred because it allows for greater pilot adjustment.

Remove the pilot

hood assembly by

unscrewing the two

attachment screws.

Pilot Orifice

LP (Propane) Orifices

Pull the pilot orifice

retainer and pilot orifice

upwards to remove.

Pilot Orifice
Retainer

Phillips
Screwdriver

Pilot Hood

Assembly

1

1

P

L

Orifice Identification:

1

6

P

L

(preferred)

NG (Natural Gas) Orifices

1

8

N

2

1

N

(preferred)

Advertising