Functions, 1. operation, 1. operation functions – Panasonic KE18NB4U User Manual

Page 47: Pam- control

Advertising
background image

Emergency operation

SENSOR DRY

AUTO cooling/heating operation

Selecting the operation mode

During DRY operation, the system adjusts the room

temperature and fan speed according to the conditions in the
room, in order to maintain a comfortable room environment.

SENSOR DRY operation

• DRY operation is as shown in the figure below.

PAM- control

• In order to further improve inverter performance, control is

switched between PWM control at low operation speeds, and
PAM control at high operation speeds, making the most
effective use of power.

The compressor operation frequency varies.
The indoor fan operates with 1/f fluctuation.

The compressor operates at a low operating frequency.
The indoor fan operates with 1/f fluctuation.

• Monitoring operation takes place when the room temperature

is below 59°F

(

15°C), or more than 5°F

(

3°C) below the set

temperature.

• When the monitoring range is entered, the compressor stops,

and the indoor fan operates with 1/f fluctuation.

DRY A

DRY B

Monitor

Conditions are monitored at all
times when the room temperature
is below 59°F(15°C).

Load

COOL zone

A zone

B zone

Emergency operation is available when the remote

controller malfunctions, has been lost, or otherwise
cannot be used.

• The set temperature is 4°F(2°C) below the detected room

temperature in the case of cooling operation, and 4°F(2°C)
above the room temperature in the case of heating
operation. The flap and fan speed settings are AUTO.

(GREEN) (RED)

(Lamp

Off)

COOL

HEAT

STOP

• When AUTO mode is selected, the microprocessor calculates

the difference between the set temperature and the room
temperature, and automatically switches to Cooling or
Heating mode.

• As shown by the example in the figure below, with AUTO

cooling/heating operation, the mode changes between
Heating and Cooling mode according to changes in the
relationship between the current room temperature and the
set temperature.

Room temp. Set temp. COOL
Room temp. Set temp. HEAT

74

Zone A

Zone B

Zone C

Zone C

Zone B

Zone A

OFF

OFF

Compressor

Operation mode

Room temp.

Heating

Cooling

Cooling

ON

ON

ON

More than

1 hour

Within
1 hour

Set temp.

Example

Example of operation in AUTO mode with the set room temperature

at 74

°

F(23

°

C).

To operate the system, press the OPERATION button,

which is also used as the receiver, below the unit display.

Each time this button is pressed, the OPERATION lamp

changes color to indicate the type of operation. Select the
desired type of operation.

8. FUNCTIONS

8-1. Operation Functions

47

Advertising
This manual is related to the following products: