GAS CONNECTION INSTRUCTIONS

Installing your

ANETS Fryer requires the fol-

lowing procedure, after its legs or casters are pro-
perly attached and it is in its desired location.

1. Ensure that the gas control valve knob

in the fryer has its OFF position next to the
valve mark.

2. Ensure that the gas supply inlet line valve is

closed (cross-wise to the pipe line direction).

3. Ensure that all fryer controls are set to OFF.

4. Connect the ¾” gas supply line to the gas line

adapter on the lower rear of the fryer.

5. Turn the gas supply line valve ON; then, con-

firm that all gas supply line joints and couplings
are free of leaks, using soap suds or a leak-
check solution, after the fryer is in its desired
location.

6. Refer to Fryer Operating Instructions to

begin using your

ANETS Fryer.

WARNING

DO NOT use a flame to check for leaks.

!