Lamp indications, Maintenance, Tightening torque – Panasonic EY7202GQW User Manual

Page 10: Factors affecting tightening torque

Advertising
background image

- 10 -

CAUTION:

To prevent the risk of fire or damage to

the battery charger.

• Do not use power source from an

engine generator.

• Do not cover vent holes on the charger

and the battery pack.

• Unplug the charger when not in use.

IV.

LAMP INDICATIONS

Red Flashing

Red Lit

Green Flashing quickly

Orange Lit

Orange Flashing

Charger is plugged into the AC outlet.

Ready to charge.

Now charging
Charging is completed.

Battery pack is warm. Charging will begin

when temperature of battery pack drops.

Charging is not possible. Clogged with

dust or malfunction of the battery pack.

V.

MAINTENANCE

Use only a dry, soft cloth for wiping the unit.

Do not use a damp cloth, thinner, benzine,

or other volatile solvents for cleaning.

VI.

TIGHTENING

TORQUE

The power required for tightening a bolt will

vary, according to bolt material and size, as

well as the material being bolted. Choose

the length of tightening time accordingly.

Reference values are provided below.

(They may vary according to tightening conditions.)

Factors Affecting Tightening

Torque

The tightening torque is affected by a wide

variety of factors including the followings.

After tightening, always check the torque

with a torque wrench.

1) Voltage

When the battery pack becomes nearly

discharged, the voltage decreases and the

tightening torque drops.

Bolt Tightening Conditions

0.5

1

1.5

2

3

2.5

M12

M10

M8

Tightening time (Sec.)

Tightening torque

M8.M10.M12 x 25mm Standard bolt
(Bolt size : Millimeters)

N

m

(k

g

f-cm)

19.6

(200)

39.2

(400)

58.8

(600)

78.5

(800)

98.1

(1000)

M8.M10.M12 x 25mm High tensile bolt

0.5

1

1.5

2

3

2.5

M12

M10

M8

Tightening time (Sec.)

Tightening torque

19.6

(200)

39.2

(400)

58.8

(600)

78.5

(800)

98.1

(1000)

117.6

(1200)

N

m

(k

g

f-cm)

Bolt

Nut

Washer

Steel plate

thickness10mm(3/8")

Washer
Spring washer

Tightening conditions

• The following bolts are used.

Standard bolts: Strength type 6.8

High tensile type 12.9

Explanation of the strength type

6.8

Bolt yield point

(80% of tenslie strength)

48 k

f/mm

2

(68,000psi)

Bolt tensile strength 60 k

f/mm

2

(85,000psi)

Advertising