Manual programming flowchart (3 of 3), Programming control 17, Figure 5 – Alliance Laundry Systems PHM1263R User Manual

Page 19

Advertising
background image

Programming Control

17

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Manual Programming Flowchart (3 of 3)

PHM1488R

Figure 5

PHM1488R

(continued)

“IrA” - Enable/disable the ability to read

the control by an external device:

“on” = Enabled

“off” = Disabled.

“t FC” (Temp Sensor only) - Set

temperature shown in Fahrenheit or Celsius.

“FH” (Temp Sensor only) - Set

the temperature of the hot water:

35°F - 194°F / 2°C - 90°C.

“FHC” (Temp Sensor only) - Set the

temperature of the warm water:

35°F - 194°F / 2°C - 90°C.

“FC” (Temp Sensor only) - Set the

temperature of the cold water:

35°F - 194°F / 2°C - 90°C.

“Codn” (Temp Sensor only) - Enable/disable

the cool down water temperature option:

“off” or 50°F - 160°F / 10°C - 71°C.

“PtEn” - Enable/disable access to the

production test cycle:

“on” = Enabled

“off” = Disabled.

“rAEn” - Enable/disable the rapid advance

feature:

“on” = Enabled

“off” = Disabled.

“nCtd” - Enable/disable whether the cycle

time will appear in display:

“on” = Enabled

“off” = Disabled.

“bALr” (VFD only) - Program the number

of times control will retry balancing the

load before moving to extract step: 1-7.

Temperature:

“CEL” = Celsius

“FAHr” = Fahrenheit

“SdAd” - Enable/disable slow drain

detection. When enabled can

increase/decrease the time before a slow

drain error will occur:

0 - 255 seconds

“dAEn” - Enable/disable the manual

diagnostics option:

“on” = Enabled

“off” = Disabled.

“FLo” - Program the low water level

during fill and tumble of all cycles:

“1” - “10”

“FnEd” - Program the medium water level

during fill and tumble of all cycles:

“11” - “20”

“FHI” - Program the high water level during

fill and tumble of all cycles:

“21” - “30”

“tCF” (Temp Sensor only) - Enable/disable a

temperature controlled fill:

“on” = Enabled

“off” = Disabled.

“ALd-” - Set the time and frequency that the

control automatically checks the water level.

“ALd3” - Auto-Water Leak Detection

Day of Week:

“0” - “127”

“ALd2”” - Auto-Water Leak Detection

Hour:

“0” - “23”

“ALd1” - Auto-Water Leak Detection:

“on”, then “0” - “127”

“oFF”

“rtC1” - Programs minutes:

“0” - “59”

“rtC2” - Programs Hours:

“0” - “23”

“rtC3” - Programs Day of Week:

“1” - “7”

“rtC4” - Programs Date of Month:

“1” - “31”

“rtC6” - Programs Year:

“0” - “99”

“rtC-” - set the control’s internal clock.

“rtC7” - Programs Daylight Saving:

“on” = Enabled

“oFF” = Disabled

“rtC5” - Programs Month:

“1” - “12”

“PCtd” - When enabled, the control

displays the programmed time during

a machine cycle:

“0” = Disabled

“1” = Enabled

Option available on Software

Version 2 or later