Auto-water leak detection “ald – Alliance Laundry Systems PHM1263R User Manual

Page 43

Advertising
background image

Programming Control

41

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

23. Auto-Water Leak Detection

“ALd”

This option allows the owner to set the time and
frequency that the control automatically checks the
water level. The owner programs which day(s) of the
week and hours of day(s) they want this test to occur.
The owner may also program this test to only occur
after XX number of machine cycles have been
completed since the last time the test was run. In order
for this Auto-Water Leak Detection test to occur, the
machine’s door must be closed.

How to Program Auto-Water Leak
Detection

1. Control must be in Manual Mode. Refer to

Entering the Manual Mode.

2. Press the #3 ( ) or the #6 ( ) keypad until

“Prog” appears in the display. Press the START
(enter) keypad and “dCyC” will appear in the
display.

3. Press the #3 ( ) or the #6 ( ) keypad to scroll

through the programmable options until “ALd-”
appears in the display. Press the START keypad
and “ALd1” will appear in the display.

4. Press the #3 ( ) or the #6 ( ) keypad to scroll

through the programmable options. Refer to
Table 11.

5. When the desired option appears in the display,

press the START (enter) keypad. The current
value will appear in the display.

6. Press the #3 ( ) or the #6 ( ) keypad to enable

during cycles, disable, increase or decrease the
hours or day.

NOTE: The hours will be displayed in military
time. For day, Sunday is considered day one (001),
Monday is day two (002) and so on.

7. Press the START (enter) keypad when the correct

value appears in the display. The next option,
“dCyC” will appear in the display.

NOTE: To program “dCyC” (Default Cycle), refer
to option 1
. To program other options, refer to the
appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to
Ready Mode.

ALd1

Auto-Water Leak Detection
(“oFF” or “0” through “127” cycles
[on] - Number of completed cycles
after which this test will occur)

ALd2

Auto-Water Leak Detection Hour
(“0” - “23” - Hour of the day this
test will occur)

ALd3

Auto-Water Leak Detection
Day of Week
(“0” - “127” - Refer to Table 4)

Table 11

>

<

>

<

>

<

>

<