Matrix switchers – Altinex 400-0026-004 User Manual

Page 22

Advertising
background image

MATRIX SWITCHERS

21

ACCESSORIES

8

Model No.

Description

RACK MOUNTING BRACKETS

DA1292RM 19”-1U Rack mount ears for rack

wide units
TABLE MOUNT BRACKETS

TM1277

3U High, 1 Rack-Wide
4 BNC TO 4 BNC COAXIAL CABLE

CB4100MR Bulk cable 4 coaxes (500 ft minimum)
CB4106MR 6 feet
CB4112MR 12 feet
CB4125MR 25 feet
CB4150MR 50 feet
CB4175MR 75 feet
CB41100MR 100 feet

5 BNC TO 5 BNC COAXIAL CABLE

CB4200MR Bulk cable 4 coaxes (500 ft minimum)
CB4206MR 6 feet
CB4212MR 12 feet
CB4225MR 25 feet
CB4250MR 50 feet
CB4275MR 75 feet
CB42100MR 100 feet

4 BNC TO 4 BNC COAX (Super
High Res.)

CB4300MR Bulk cable 4 coaxes (500 ft minimum)

5 BNC TO 5 BNC COAX (Super
High Res.)

CB4400MR Bulk cable 5 coaxes (500 ft minimum)

OPTIONAL CONTROL
ACCESSORIES

CP-01

Front Panel control

CP-02

Remote control pad w/cable

CP-03

Touch screen LCD Display control
panel w/cable

FAQ (Frequently Asked Questions)

9

No:

Question

Answer

1

How do I know
what input is
connected to
what output?

This information must be
maintained by the control
system. The present
version of the software
does not track that
information.

2

My modules do
not
communicate
with each
other?

When you experience lack
of communication check
the following:
1. Cable connections.
2. Unit ID settings.
3. Same Baud rate
settings.

3

Can I control
multiple
switchers with
one RS-232
card?

Yes. You can control up to
14 different groups of
switchers. Just connect the
Loop out port to the next
switcher’s Loop in port
using provided cables.

4

Does the
HOMERUN
come with the
rack mounts?

Yes, two 1-U high rack
mounts are included with
each module. Please
check the packaging
carefully.

5

How does one
increase the
number of
inputs or
number of
outputs on the
switcher?

To increase the number of
inputs one can add second
switcher and loop some of
the outputs (say 8) of the
first switcher to the 8
inputs of the second
switcher, thus creating a
24x8 Matrix Switcher. To
increase the number of
outputs use a second
switcher and a VA6834FC
interface with dual output,
or 1 in 2 out DA at each of
the inputs. This will
increase the matrix size to
16x32. For other
configurations call Altinex.

6

Can I switch
each module
independently?

Yes. Using proper RS-232
commands, one can
control each level of
switching independently by
assigning a unique ID
number

7

If I need to use
a switcher to
switch
RGBHV,
Composite
Video, S-Video
and/or Audio

Yes, the HOMERUN
Switcher can switch
RGBHV, Composite Video,
S-Video and/or Audio at
the same time.
Contact Altinex if you have

Advertising