1. Read and follow all instructions, cautionary markings

and make sure power source conforms to requirements
of equipment.

2. Follow all local electrical and safety codes, as well as

the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSHA) in the Unit-
ed States, including fire rated construction. Ground
motor in accordance with NEC Article 250, (grounding).

3. Avoid extension cords. If used, assure it is UL rated and

of proper type, gauge, and length. Never operate more
than one fan from a single extension cord.

4. Do not kink power cord or allow it to contact oil, grease,

hot surfaces, sharp objects, or chemicals. Replace worn
or damaged cord immediately.

5. Do NOT use general purpose circulators in flammable,

explosive, chemical-laden, or wet or rainy atmospheres.
Use special purpose circulators designed for that
application. Do not attach ductwork to a circulator.

6. In critical applications, use a suitable alarm (air switch,

temperature sensor, etc.) should the circulator
malfunction.

Installation

Where power cord is not provided, connect power to the

motor in accordance with the United States NEC and all
local codes. Motor terminal connection data is provided on
the motor nameplate or on the motor terminal box cover
plate. Use adequate size wire for all branch and feeder
runs.

a. Dock Door Fan (Model CAC-DF): Refer to Page 6, for

correct positioning of parts.

b. Mobile Air Circulators and High Volume, High Velocity

Industrial Fans (Models CAC-M, CAC-WH & CAC-FH):
Locate the fan in the desired location on a stable, level
surface, or on ceiling for ceiling mounted high volume,
high velocity industrial fans. Connect the power cord or
wire unit per all National and Local

Motors may be equipped with automatic reset thermal
protection. Motor may activate without warning.

Do not place body parts or objects in circulator, motor
openings, or drives while motor is connected to the
power source.

To reduce the risk of fire, electric shock, or injury to
persons, observe the following: Do not use a three-prong
to two-prong adapter on the power cord. Do not use
circulators with a solid state speed control device. Do not
depend on any switch or thermostat to disconnect power
supply. Always unplug the power cord.

Installation, troubleshooting, and parts repair to be per-
formed only by qualified personnel.

Electrical Codes as required.
c. Washdown Air Circulators

(CAC-WW): After
mounting motor, remove
drain plugs.

Operation

1. CAC-P, CAC-W, CAC-PO and CAC-WO are operated

by pulling chain: High - Low - Off

2. CAC-M operates by rocker style switch: On - Off
3. CAC-DF operates by two-speed rocker style switch:

Low - Off - High

4. CAC-FH, CAC-WH, CAC-WW and CAC-WX requires

service switch wired by others.

Maintenance

1. Periodically clean propeller, guard, and motor of any

excessive dirt accumulation. Allow unit to cool; motors
can be hot enough to cause injury.

2. Follow motor manufacturer’s instructions for motor

lubrication.

IMPORTANT: When making repairs, use only Loren Cook
authorized repair parts.

Wall/Ceiling Bracket

1. For mounting circulator to wall, post, or ceiling.

Adjustable pivot bracket allows omni-directional air
circulation.

2. Furnished with secondary support cable for use when

circulator is mounted overhead. NOTE: Not
recommended for use with oscillating circulators when
ceiling mounted.

Wall/Ceiling Bracket Assembly Instructions

(Refer to Figures 1 and 2)

1. The wall/ceiling bracket should be assembled with the

swivel bracket as shown in the appropriate illustration.
The bracket has two holes; be sure smaller hole is as
specified in the illustration.

2. Locate the

wall or ceiling
stud nearest
the desired
fan location.
Attach the
bracket to the
stud using (3)
5/16 x 2”lag
screws or
appropriately sized bolts and nuts if attaching to I-
beams.

NOTE: Always install the

bracket to a minimum of 2 x
4 studding.

3. Position the swivel bracket

in the motor yoke (or along
side the oscillation circular
cast aluminum support
bracket) and align the pivot
hole with the larger hole in
the swivel bracket.

4. Insert the larger dia. bolt in

the pivot hole and install
the lock nut finger tight.

5. Insert the smaller dia. bolt in the slot in the motor yoke

Circulator

Mounting Bolt

Mounting Nuts

Mounting

Bolts

Swivel Bracket
(Smaller Hole Down)

Mounting Nut

Wall
Stud

10-7/8"

5-7/16"

Figure 1 - Wall Mounted Assembly

Mounting

Bolts

Swivel Bracket
(Smaller Hole Down)

5-7/16"

Circulator

Mounting
Nuts

Mounting
Bolt

Mounting
Nut

10-7/8"

Figure 2 - Ceiling
Mounted Assembly