HOUNO M ovens User Manual

Page 4

Advertising
background image

4

(1) Main switch

Turn the main switch to the desired operating mode (9 – 12).

Set the time switch

(2), the oven chamber temperature switch

(3) or the core

temperature switch

(4) and the steamer starts automatically

Before the steamer starts, all displays and control lamps light up for approx. 2 seconds to
indicate that all functions are being automatically tested.

(2) Time

The time can be set from 1 min. to 3 hours.

When the time has run out, the steamer automatically stops and an alarm sounds.

The pre-set time can also be changed while the program is running.

Continuous operation

Set the steamer at continuous operation by turning past 3 hours until --:-- appears.

If the core temperature is on at the same time, the steamer stops when the core temperature is
reached.

(3) Oven chamber temperature

The temperature range depends on the operating mode chosen:-

•HOT AIR

20 - 250°C

•COMBI STEAMING

20 - 250°C

•STEAMING

20 - 100°C

The temperature can be changed any time during the program.

(4) Core temperature

The core temperature range is 20 – 99°C.

(5) Display for core temperature

When the core temperature is activated, this is shown in the display. When the steamer is off,
the pre-set temperature is shown; when the steamer is on, the actual temperature is shown.

Advertising