Warning – Nieco JF62 User Manual

Page 10

Advertising
background image

11

Nieco Corporation - Model JF62/62-2G

C.2 lighting Procedures

1. Broiler is

centered under

hood and

plugged in

2. Gas valve is

open when

handle is in line

(parallel to) the

pipe

3. Turn ventilation

system on

The JF62 is equipped with automatic ignition. When the broiler is turned on, a hot surface ignitor turns on 5 seconds

before the flow of gas. Gas then flows to all of the burners. If the burners are not lit within 10 seconds, the control will

reset and try again for 10 seconds. This occurs 3 times. If the broiler does not light after the third attempt, the ignition

failure light will flash and the main on/off switch must be cycled to repeat the procedure. If this still doesn’t light the

broiler, see the MANUAL IGNITION instructions.

WaRnInG

THe VenTIlaTIon sYsTeM MUsT

be on aT all TIMes DURInG

bRoIleR oPeRaTIon. oPeRaT-

InG bRoIleR WITHoUT PRoPeR

VenTIlaTIon Is a seVeRe fIRe

HaZaRD.

noRMal IGnITIon

PRe-lIGHTInG PRePaRaTIon

1. Turn the MaIn PoWeR sWITCH on.

1.

2.

2. Allow broiler to heat for 45 minutes before cooking.

Advertising