Nieco N2500 User Manual

Page 12

Advertising
background image

12

D.2 Lighting Procedures

1. Broiler is

centered under
hood and
plugged in

2. Gas valve is

open when
handle is in line
(parallel to) the
pipe

3. Turn ventilation

system on

1

Turn the MAIN POWER SWITCH (a) on. The N2500
is equipped with automatic ignition.

2

After ignition; check GAS PRESSURE GAUGE (a)
reading. Gauge should read 5”. If not, follow ignition
troubleshooting tips of this manual. Verify that all
burners - upper and lower - have lit.

a

WARNING

THE VENTILATION SYSTEM MUST
BE ON AT ALL TIMES DURING
BROILER OPERATION. OPERATING
BROILER WITHOUT PROPER
VENTILATION IS A SEVERE FIRE
HAZARD.

AUTOMATIC IGNITION

PRE-LIGHTING PREPARATION

a

Nieco Corporation - Model N2500

1. Allow the broiler

to run free of
any product for
10 minutes.
This will burn
the chain clean.

2. Turn off the

Main Power
Switch (a)
.

3. Wait for 30

minutes for the
broiler to cool.

D.3 Shutdown Procedures

a

PLANNED SHUTDOWN

WARNING

Always leave the ventilation hood
on while the broiler is cooling.
Failure to do so is both a fire risk
and could result in damage to the
broiler.

CAUTION

Allow the broiler to fully cool
BEFORE beginning disassembly
and cleaning. Failure to do so
could result in serious injury.

2. Close the MAIN

GAS VALVE (b)

Valve is closed
when it is perpen-
dicular to pipe

EMERGENCY SHUTDOWN

1. Turn off the

MAIN POWER
SWITCH (a)

a

b

Your Nieco Automatic Broiler is designed to automatically stop gas flow to the broiler in the
event of power failure, gas pressure loss or any other related incident. No attempt to operate
this appliance should be made in the event of a power failure.

Advertising