Pitco Frialator Solid State Temperature Control User Manual

Page 2

Advertising
background image

Solid State Temperature Control (SSTC)

L20-314 Rev 0 (9/7/07)

Page 2

1

Switch and Indicator Locations and Function:

On / Off switch:

Turns the control on or off. The power indicator
will be illuminated when the switch is in the on
position.

Primary / Backup select switch:

In appliances with primary AND a backup control, this
switch selects the control that will manage
temperature in the appliance. When the switch is in
the single dot position, power is diverted to the
primary control, typically an I12 cooking computer.
When the switch is moved to the two dot position,
power is diverted to the Backup control.

Melt / No Melt select switch:

In the melt cycle position, melt cycle will be executed
when the appliance first starts up. This melt cycle will
end automatically when the temperature conditions
are correct to allow full heat. Operators may bypass
a running melt cycle by moving the switch to the full
heat position.

Temperature Set Knob:

The position of the pointer sets the cooking
temperature of the control. Scales are shown in
Fahrenheit and Celsius scales.

Power Indicator:

This green indicator shows the control is turned on.

Heat Demand Indicator:

This LED indicator shows when the control is
demanding heat.

Heat Feed Back/Fault Indicator:

This indicator shows when the appliance is heating in
response to a heat demand. Under normal
conditions, this light will follow the head demand
indicator. This indicator is also used to flash
conditions for probe faults, drain valve open
conditions, or, boil out operations.

PRIMARY

BACKUP

FLAT BOTTOM

Advertising