17

Identification of the UPM connector terminals is helpful for troubleshooting.
Disconnecting the wiring harness connector and conducting voltage or ohm
measurements on the terminals in the connector will help determine the condition of the
components connected to the wiring harness. The pin numbers are identified on the
schematic for determining the component connections.

The 24 pin connector for the UPM is identified on the schematic as “J1”. It carries the
majority of the communication signals to and from the UPM. The connector is designed
so that it can only be connected in the correct orientation. Identification of the pin
numbering is shown below.



















6.1a Programming Interface

The programming interface allows direct access to the settings in the UPM operating
program. The functions in the program can be turned adjusted to tailor the machines
operation to a specific application. The timers can be adjusted to coordinate with
functions such as the fill rate of the wash and sanitizer tanks. Explanation for how to set
these control functions and timers is located in the programming manual number 37193.

The programming interface is installed in the mounting bracket by separating the outer
case from the inner frame. Press the thumb tabs toward the center of the case, and
then pull the outer case away from the front face.

Pin 13 is located
in the upper left
corner when
facing the
connector

Pin 1 is located in the
lower row on the left
corner when facing
the connector

Pin 12 is located in
the lower right
corner when facing
the connector. The
lower row is
numbered 1 thru 12

Pin 24 is located
in the upper right
corner when
facing the
connector. The
upper row is
numbered 13 thru
24

Orient the connector with the clip on top as shown