Power Soak 37179 PS-275 Service Manual User Manual

Page 44

Advertising
background image

38

9.1 The pump will not start when the green “START” button is
pushed.

9.1a. Control panel white POWER light is not on.

Possible Cause
1. The power supply to the machine is turned off.
2. The transformer has failed.

Solution
1. Restore power to the machine; check the circuit breaker in the wall mounted

enclosure.

2. Check the transformer output (see section 6.5)

9.1b. Control panel white POWER light is on.

Possible Cause
The Wash Tank is empty.

Solution
Fill the wash tank with water and detergent according to the instructions in the
operator’s manual.

9.1c. Control panel POWER (white) light is on, STATUS (green) light is on

and WASH TANK (blue) light is on.

Possible Cause
The Wash Tank is empty or the wash solution life cycle has expired.

Solution
Fill the wash tank with water and detergent according to the instructions in the
operator’s manual. If the wash tank is full, the life of the wash solution has expired; the
tank must be drained and re-filled.

9.1d. Control panel POWER (white) light is on, STATUS (green) light is on

and SANATIZER TANK (red) light is on.

Possible Cause
The Sanitize Tank is empty or the sanitize solution life cycle has expired.

Solution
Fill the sanitize tank with water and sanitize solution according to the instructions in the
operator’s manual. If the sanitize tank is full, the life of the sanitize solution has expired;
the tank must be drained and re-filled.

Advertising