Refer to the following table when setting the DIP switches.

Wiring Devices to the AXB-EM232

The AXB-EM232 has captive-wire connectors on the rear panel (FIG. 1) for AXlink, RS-232, RS-

232, RS-422, and 12 VDC power.

Preparing captive wires

1.

Strip 0.25 inch of wire insulation off all wires.

2.

Insert each wire into the appropriate opening on the connector according to the wiring

diagrams and connector types described in this section.

Do not tighten the screws excessively; doing so may strip the threads and damage the

connector.

Using AXlink

Connect the AXlink wiring to the connector on the AXB-EM232, as shown in FIG. 3.

Communication Parameters DIP Switch Settings

Switch

1

2

3

4

5

6

7

8

Function Stop Bits Data Bits

Parity

Baud Rates

Setting

Off

Off

Off

Off

Off

Off

Off

Off

Value

2 bits

7 bits

Unused

300

On

On

On

Off

Off

On

Off

Off

1 bit

8 bits

Unused

600

Off

On

Off

Off

On

Off

Unused

1,200

On

On

Off

On

On

Off

Unused

2,400

Off

Off

On

Off

Off

On

Mark

4,800

On

Off

On

On

Off

On

Even

9,600

Off

On

On

Off

On

On

Odd

19,200

On

On

On

On

On

On

None

38,400

FIG. 3 AXlink wiring

PWR

AXP

AXM

GND

PWR

AXP

AXM

GND

AXlink

Device