TECHNICAL MANUAL

SILVER KING DROP-IN MERCHANDISERS

Thank you for purchasing Silver King food service equipment. Our goal is to provide our customers with the most

reliable equipment in the industry today. Please read this manual and the accompanying warranty information before

operating your new Silver King unit. Be sure to complete and mail the warranty card within 10 days of purchase to

validate your warranty.

INSPECT FOR DAMAGE AND UNCRATE

Upon delivery of your new Silver King unit, uncrate at once to inspect for possible damage following the instructions

printed on the exterior of the container. Report any damages to the carrier responsible for transportation and promptly

present a claim for any evidence of mishandling. Save all packaging materials if a claim is to be filed.

INSTALLATION

After removing the unit from the packaging, wash the interior and exterior surfaces using a warm, mild soapy water

solution and a sponge or cloth, rinse and wipe dry.

Lid

For shipping purposes the Lid Assembly has been taped to the cabinet. Remove all the tape from the Lid Assembly and

install the Lid Assembly on the cabinet by holding in the hinge pins at the back of the Lid Assembly and inserting them

into the holes in the Hinge Brackets on the cabinet.

Location

When locating your counter-top drop-in display merchandiser, convenience and accessibility are important consider-

ations, but the following installation guidelines must be followed;

*When installed in a countertop, provisions need to be in place for the unit to receive proper ventilation for the compres-

sor. The drawing on the opposite page shows minimum ventilation requirements for the unit. Do not install the unit in

cabinetry that does not have provisions for ventilation as that would void all warranties.

*Always avoid placing the unit next to an oven, heating element or hot air source that would affect the operation of the

unit.

*The unit must be level.

*The counter must be able to support a minimum of 150 pounds.

Electrical Connections

Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to

power. The specifications on the data plate supersede any future discussion.

The standard counter-top display merchandiser is equipped with an eight (8) foot power cord that requires a 115 Volt,

60 Cycle, 1 phase properly grounded electrical receptacle. The power cord comes with a 3 prong plug for grounding

purposes. Any attempt to cut off the grounding spike or to connect to an ungrounded adapter plug will void the warranty,

terminate the manufacturers responsibility and could result in serious injury.

The electrical circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit

and not plugged into an extension cord.

OPERATION

Initial Start Up

After satisfying the installation requirements, the counter-top drop-in display merchandiser is ready to start. The unit

will start when the power cord is connected to the required power source. If the compressor does not start when the unit

is initially plugged in, check to make sure that the Temperature Control is not in the ‘off’ position. Allow the unit to run for

two hours before loading it with product. When loading the unit with product do not load above the ‘product load line’

indicated on the liner.