Silver King SKMBDI User Manual

Page 3

Advertising
background image

2

Temperature Control

The Temperature Control is located on the front of the lower condensing unit. Turn the Temperature Control stem

clockwise to obtain colder cabinet temperatures and vice versa. Allow the unit a minimum of two hours to respond to a

control setting adjustment.

Defrost

The Silver King counter-top drop-in display merchandiser is a manual defrost unit. The unit should be defrosted when-

ever the walls accumulate a frost layer that is 1/4 inch thick. To defrost the unit, either turn the Temperature Control stem

to the ‘off’ position (fully counterclockwise) or disconnect the Power Cord from the electrical receptacle, and remove the

Lid Assembly. After the frost has melted or come loose from the walls, wipe out the cabinet interior. Do not attempt to

scrape or chisel off the frost as you could do irreparable damage to the unit.

MAINTENANCE

Preventative maintenance is minimal although these few steps are very important to continued trouble free operation

and maximizing the life of your appliance.

Cabinet Surfaces

The cabinet interior and exterior surfaces should be cleaned periodically with a solution of warm water and mild soap,

rinsed and wiped dry with a soft cloth. A good stainless steel cleaner can also be used. Should a surface become

discolored, do not attempt to clean with an abrasive cleanser or scouring pad. Use a soft cleanser and rub with the

grain of the metal to avoid scratching the surface. Do not use chlorinated cleaners on the stainless steel.

Condenser

Periodically, accumulated dust must be removed from the condenser. First, disconnect the unit from the power supply.

To clear the dust, blow air though the condenser fins or remove the protective screens and brush the dust from the

backside of the condenser.

P/N 90064

MODEL____________________ SERIAL NO.______________________ DATE INSTALLED___________________

Recommended Installation And Ventilation

Openings For Drop-In Models

Front & Rear Vents Are Required For

Proper Air Flow To Condensing Unit

Opening in Counter

Air Flow

10

11

24-1/4

18

20-3/4

21-1/4

21

24