Electrical Connections

Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the unit to a power

source. The specifications on the data plate supersede any future discussion.

The standard unit is equipped with an eight (8) foot power cord that requires a 115 Volt, 60 Cycle, 1 Phase properly grounded

electrical receptacle. The power cord comes with a 3 prong plug for grounding purposes. Any attempt to cut off the grounding

spike or to connect to an ungrounded adapter plug will void the warranty, terminate the manufacturers responsibility and could result

in serious injury.

The circuit must be protected with a 15 or 20 ampere fuse or breaker. The unit must be isolated on a circuit and not plugged into an

extension cord.

OPERATION

Initial Start Up:

After satisfying the installation requirements, the unit is ready to start. The unit will start when the power cord is connected to the

required power source. If the compressor does not start when the unit is initially plugged in, check to make sure that the

temperature control is not in the ‘off ‘ position. Allow the unit to run a minimum of two hours before loading it with product.

Temperature Control

The Temperature Control is located on the back wall of the cabinet liner and is factory set to maintain an average cabinet

temperature of 35 to 40 Deg. F.. To access the temperature control, remove the top drawer from the cabinet, (top right drawer on

model SKRCB79). To obtain colder temperatures turn the Temperature Control stem clockwise and visa versa. Allow the unit a

minimum of one hour to respond to a control setting adjustment.

Defrost

Your Silver King unit is an automatic defrost unit. No additional plumbing is required. Defrost water is collected in a pan located in

the compressor compartment where it is evaporated into the room air. It is important that the unit be level so the condensate can

drain properly.

MAINTENANCE

Preventative maintenance is minimal although these few steps are very important to continued operation and maximizing the life of

the appliance.

Cabinet Surfaces

The cabinet interior and exterior are stainless steel. These surfaces should be cleaned periodically with a solution of warm water

and mild soap. After cleaning the surfaces should be rinsed with clean water and wiped dry with a soft cloth. Stainless steel

cleaners can also be used. Should a surface become stained, do not attempt to clean with an abrasive cleaner or scouring pad.

Use a soft cleanser and rub with the grain of the metal to avoid scratching the surface. Always rinse well and dry after cleaning.

Do not use chlorinated cleaners.

Condenser

Periodically, dust on the condenser coil must be cleaned. The condenser is located behind the front cover at the right front of the

unit. Remove the front cover by removing the two (2) screws at the left side of the cover and swinging the cover off the cabinet.

The condenser will be exposed. Clean the accumulated dust/debris from the condenser with a vacuum or brush. This will need to

be done regularly to maintain the compressor warranty!

Drawer Wheels

Lubricate the drawer whells periodically to obtain maximum life from the wheels.

Casters

Check to make sure that the casters are installed tightly to the cabinet.