Secondary

MASTER Camera Set #1 - Control A

Camera Set #2 - Control B

Camera Set 1

Camera Set 2

LINK IN

LINK OUT

Cat-5e

Cat-5e

Cat-5e

Primary

LINK OUT

LINK IN

Precision Camera Controller

Cat-5e

Drawings: System Configurations Examples


Sample Configuration 1:

Precision Camera Controller connected to seven (7) PTZ
cameras (like Vaddio HD-20s) directly.










Sample Configuration 2:

Two Precision Camera Controllers set up in Link Mode. The Precision Camera Controller with the cameras connected is the
Primary, and the Precision Camera Controller without cameras is the Secondary unit. There can be two operators, but only
one operator can access the cameras at a time (Cessna 172 not included).

















Sample Configuration 3:

Two Precision Camera Controllers set up in Link Mode. Each Precision Camera Controller has 7 cameras connected, and all
cameras can be controlled from either Precision Camera Controller, however not concurrently. There can be two
operators, but only
one operator can access all fourteen cameras at any point in time. As an example, both the Master
and the Secondary can operate their own Control A bus cameras concurrently, but in order for the Master to control the B bus
of the Secondary Precision Camera Controller, then operator at the Secondary position must remain idle. An external
switcher may not be connected to Precision Camera Controller in Dual Link mode. Both Precision Camera Controllers must
be set to Control A under the Camera Select Bus menu.