TO REPLACE UV BULB AND BALLAST

TO REPLACE THE HEPA FILTER

STEP 1

Turn power off and

Unplug the unit.

Lay unit up-side down.

STEP 2

Remove all four screws

with a screwdriver.

STEP 3

Gently grasp wheels.

STEP 4

Remove base

by gently

pulling on

the wheels.

STEP 5

First remove the

Carbon filter

by placing thumbs on
the inner side of the filter.

Then pull up gently

to remove filter.

To refill the Carbon Canister without changing the HEPA filter
go to STEP 7 on page 5.

STEP 6

Remove the HEPA filter

by placing thumbs on the

inner side of the filter

and grip the filter.

HEPA filter : 3 to 5 years depending on use.

HEPA Filter Order Guide

Models

4000

5000

6000

8000

Exec, Vocarb

A4FH0411

A5FH0411

A6FH0411

A8FH0411

MCS

A4FH0420

A5FH0420

A6FH0420

*Please use the above part numbers when ordering your replacement parts

Step 1

Turn power off

Lay unit up-side

down.

With screw driver
remove 4 screws.

Gently grasp
wheels.

Remove lit by pulling
slightly on wheels

Removing Filters

Remove the filter(s)
depending on
your model

Carbon Filters

HEPA Filters

Step 2

Step 3

Step 4

Step 5

Step 6

Remove the
three screws that
hold in
the filter end plate
and remove

Step 8

Place the new
bulb in the
holder and check that
the bulb is horizontal
and not touching
anything before
tightening the nut.

Step 9

After securing the wing nut,
replace the 4 prong connector
which only
connects one-way.
"Notice the prongs are wider
one way than the other"

Notes:

Replace the filter end plate making sure the aluminium side is down
toward the side of the bulb.
Replace the screws, filter(s) and bottom with the 4 screws

4 pin socket

7A

Step 7- 10 W Lamp

A.

Unplug the 4 pin

socket from the UV light bulb.

B.

Loosen the wing nut that holds

the UV light bulb
in place and remove bulb

7B

Wing Nut

7A

Step 7 - 20W Lamp

B.

Unplug the 4 pin

socket from the UV light bulb

A.

Cut the nylon tie wrap

that was holding the
UV light bulb in place during
shipping

7B

Nylon wrap