Warning – AllerAir 4000 User Manual

Page 4

Advertising
background image

ALLERAIR'S AIR PURIFICATION SYSTEM

LASER TESTED TRUE HEPA

HEPA (Hight Efficiency Particulate Arrestance) filters were develped for the Atomic

Energy Commission to remove radio active dust from their laboratories. The are now the

primary filtration systems for electonic clean room assembly, hospital surgeries, bio

engineering, pharmaceutical laboratories and any other space where clean air is critical.

HEPA will trap microscopic dust which will give you distress from allergies, asthma,

respiratory problems, chemical sensitivities and sick building syndrome. It will trap

99.97% of all particles down to 0.3 microns (including bacteria, dust mite antigens,

respiratory particles, fungal and other microbiologicals. For these reasons that HEPA

filtration is recommended by more allergists, medical professionals and clean air

consultants than any other filter system available.

CARBON FILTER (ACTIVATED AND GRANULATED)

We use only activated granular carbon mixed with zeolite and specially impregnated

carbons. We stay away from dust carbon which has been impregnated onto a poly or

foam material. This type of carbon filter has to be changed as often as every week to be

fully effective. AllerAir's carbon filter can last up to 2 or 3 years and more, depending on

the level of toxins in the area.

The activated carbon we use is derived from coconut shell and can adsorb up to 60% of

its own weight in toxic gases, fumes and chemicals. These toxic substances make us ill,

and are found in every home, office and industry.

OTHER FILTERING SYSTEMS AVAILABLE

Ozone generators, negative ion machines and electrostatically charged units all

generate ozone which is a toxic substance. Any unit which provides ozone cannot be

recommended by Health and Welfare or by the Lung Association.

AllerAir's units on the other hand do not produce any ozone whatsoever. The latest air

purification technology does not add anything to the air (especially impurities like

ozone or P.V.C.s). AllerAir's unit scrubs impurities and toxins out of the air.

ENERGY COSTS

We use a high efficiency motor which cost pennies a day to operate in contrast to

almost all other manufactures who use the lowest price motor available. One of the

reasons we can offer a five year extendible to ten year warranty is because of the

sophisticated motor we use. We have spared no effort to give you the most for the least.

ADDITIONAL INFORMATION

The rush of air on "Low", makes less noise which is often used to help people sleep more

soundly. Use "High" in work places or home living rooms. Use "Turbo" when you are out

of the area for the day or night. The sound you hear from the unit is the sound of the air

passing through the vent to achieve a current so that your complete area will receive

changes of air.

The air coming out of the unit may feel cool to your hand, but the temperture of the air

is actually the same. And AllerAir units are specially designed to have no offgasing

because our entire unit housing is made of steel.

IMPORTANT NOTICE

To receive maximum use of HEPA filter media when used in freshly painted room, you

should first remove the HEPA filter from the unit to avoid contaminating the HEPA

media. Turn unit off and Ungplug unit. Remove bottom screws. Open bottom of unit,

Grasp outer filter ring firmly with both hands and remove carefully. Close unit, plug into

grounded receptacle then turn on. Replace carbon filter before reinstalling HEPA filter.

Do not allow any object to be stuck or poked into any opening of the unit.

Never service the unit before turning unit off and removing electrical plug

from the wall receptacle.

TO REPLACE OR CLEAN THE PRE-FILTER

STEP A

Turn off the unit.

Unplug the unit.
Gently tilt over the unit.

STEP B

Remove the pre- filter

gently to avoid disturbing
the dust on it.

Either
Vacuum the pre-filter
on both sides and replace.

Or
Place the old pre- filter in a garbage bag
for disposal.

STEP C

Replace the new or cleaned
pre-filter by gently pressing
against inner carbon filter.

Gently return the unit to the
upright position.

Before removing the top or bottom off the unit for any reason, unplug the unit.
Do not allow any object to be stuck or paked into any opening of the unit.

(i.e. louvers or control knob.)

Warning

Pre - filter : Vacuum every 1 or 2 months. Replace when necessary.

HIGH for regular daytime use

Wipe the unit with a damp cloth.
Plug the unit into a grounded 110 outlet.

TURBO and let it run for a moment.

Place the unit in the desired area and set at

and at LOW for overnight.

The most effective way to use the air purifier is to run it on low

Turn the unit on at

TO BEGIN USING THE AIR PURIFIER

Prefilters Order Guide*

Models

Prefilters

4000

5000

6000

8000

Notes

Exec, Vocarb

Poly Prefilters

A4FMP006

A5FMP009

A6FMP012

A8FMP008 packs of 4 or 8

DS Models

Tacky Prefilters A4FMPS06

A5FMPS09

A6FMPS12

packs of 10

MCS Models

Cotton Prefilters A4FCP016

A5FCP019

A6FCP022

packs of 6

*Please use the above part numbers when ordering your replacement parts

AllerAir Industries Inc.

Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com

AllerAir Industries Inc.

Toll free: 1-888-852-8247 / Fax: 1-877-688-2193 www.allerair.com

7