A72881_sht2, Installation instructions, Caution – American Electric Lighting 247L User Manual
Page 2
American Electric Lighting a division of Acuity Lighting Group, Inc. Newark, OH
DRAWING NO. A72881 REV --
(BACK)
©2013 ACUITY LIGHTING GROUP, INC.
PART NUMBER 057-70-72881
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
AMERICAN REVOLUTION POST TOP 247 LED SERIES
AMERICAN REVOLUTION POST TOP 247 LED SERIES
cont.
cont.
MOUNTING:
MOUNTING:
NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN
NOTE: THIS UNIT WILL ACCEPT POLE TOPS WITH AN
EXTERIOR DIAMETER BETWEEN 2.375” AND 3“
EXTERIOR DIAMETER BETWEEN 2.375” AND 3“
1. WHEN PLACING THE UNIT ON THE POLE, FEED THE
1. WHEN PLACING THE UNIT ON THE POLE, FEED THE
SUPPLY LEADS THROUGH THE BASE OF THE UNIT.
SUPPLY LEADS THROUGH THE BASE OF THE UNIT.
NOTE: IF UNIT IS PRE-WIRED, FEED THE SUPPLIED
NOTE: IF UNIT IS PRE-WIRED, FEED THE SUPPLIED
PRE-WIRE THROUGH THE POST TOP AND DOWN THE
PRE-WIRE THROUGH THE POST TOP AND DOWN THE
POLE.
POLE.
2. ORIENT THE UNIT SO THAT THE CLOSURE SCREW
2. ORIENT THE UNIT SO THAT THE CLOSURE SCREW
(OR TRIGGER LATCH IF EQUIPPED) ARE TO THE
(OR TRIGGER LATCH IF EQUIPPED) ARE TO THE
STREET SIDE.
STREET SIDE.
3. TIGHTEN THE THREE MOUNTING SET SCREWS.
3. TIGHTEN THE THREE MOUNTING SET SCREWS.
WIRING:
WIRING:
NOTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS
OTE: THIS PROCEDURE IS NOT NECESSARY IF UNIT IS
SUPPLIED WITH PRE-WIRE.
SUPPLIED WITH PRE-WIRE.
1. OPEN THE UNIT AND REMOVE THE STREET SIDE LENS.
1. OPEN THE UNIT AND REMOVE THE STREET SIDE LENS.
2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE
2. LOCATE THE WIRING DIAGRAM ATTACHED TO THE
INSIDE OF THE HOOD.
INSIDE OF THE HOOD.
3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT
3. USING THE WIRING DIAGRAM AS A GUIDE, CONNECT
THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.
THE POWER SUPPLY LEADS TO THE TERMINAL BLOCK.
4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE
4. CONNECT THE GREEN OR BARE GROUND SUPPLY WIRE
TO THE CASTING BY HOOKING IT AROUND THE HEAD OF
TO THE CASTING BY HOOKING IT AROUND THE HEAD OF
THE GREEN GROUNDING SCREW, LOCATED BESIDE THE
THE GREEN GROUNDING SCREW, LOCATED BESIDE THE
TERMINAL BLOCK, AND TIGHTENING THE SCREW
TERMINAL BLOCK, AND TIGHTENING THE SCREW
SECURELY.
SECURELY.
5. REINSTALL THE STREET SIDE LENS.
5. REINSTALL THE STREET SIDE LENS.
6. CLOSE THE UNIT.
6. CLOSE THE UNIT.
PHOTOCONTROL CONT:
PHOTOCONTROL CONT:
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
NOTE: FOR ELECTRICAL SAFETY PURPOSES, THE CUPOLA IS
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DESIGNED SO THAT IT WILL NOT TURN BEYOND 360 DEGREES.
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
DEPENDING ON THE INITIAL ORIENTATION, IT MAY BE NECESS-
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
ARY TO TURN THE CUPOLA IN THE OTHER DIRECTION IF IT
STOPS AND REFUSES TO TURN.
STOPS AND REFUSES TO TURN.
L ADDER REST INSTALLATION:
ADDER REST INSTALLATION:
NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.
NOTE: IT IS DESIGNED TO BREAK-AWAY UNDER SIDE FORCE.
HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT
HOWEVER, IT CAN BE REATTACHED WITH A 1/4-20X3/4 BOLT
AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT
AND NUT AVAILABLE IN THE LADDER REST REPLACEMENT KIT
(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)
(THE KIT ALSO CONTAINS TWO ADDITIONAL LADDER RESTS.)
NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED
NOTE: THE LADDER REST IS A PRESS FIT DESIGN INTENDED
FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE
FOR INSTALLATION AFTER THE UNIT IS INSTALLED ONTO THE
POST TOP.
POST TOP.
1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE FIGURE 3)
1. INSERT THE PIN FEATURE ON THE LADDER REST (SEE FIGURE 3)
INTO THE LADDER REST HOLE LOCATED ON THE LEFT AND
INTO THE LADDER REST HOLE LOCATED ON THE LEFT AND
RIGHT SIDE OF THE LOWER HOUSING JUST ABOVE THE MOUNT
RIGHT SIDE OF THE LOWER HOUSING JUST ABOVE THE MOUNT
SET SCREWS.
SET SCREWS.
2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK THE
2. USING A RUBBER MALLET OR HAMMER, GENTLY KNOCK THE
LADDER REST INTO THE HOLE. BE SURE TO KEEP THE LADDER
LADDER REST INTO THE HOLE. BE SURE TO KEEP THE LADDER
REST LINED UP WITH THE HOLE SO THAT THERE IS NO
REST LINED UP WITH THE HOLE SO THAT THERE IS NO
DAMAGE TO THE PIN.
DAMAGE TO THE PIN.
NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE
NOTES: IF THE PIN IS DAMAGED BEYOND REPAIR, REMOVE
IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT
IT WITH PLIERS AND REATTACH USING A 1/4-20X3/4 BOLT
AND NUT.
AND NUT.
CAUTION
DO NOT TIGHTEN SET SCREWS
BEYOND 15 ft-lb. TORQUE.
!
PHOTOCONTROL:
PHOTOCONTROL:
NOTE: NO TOOLING IS NECESSARY FOR THE PHOTO-
NOTE: NO TOOLING IS NECESSARY FOR THE PHOTO-
CONTROL INSTALLATION OR ADJUSTMENT.
CONTROL INSTALLATION OR ADJUSTMENT.
- IF NO PHOTOCONTROL OPTION WAS SELECTED, A
- IF NO PHOTOCONTROL OPTION WAS SELECTED, A
CUSTOMER SUPPLIED PHOTOCONTROL WILL NEED
CUSTOMER SUPPLIED PHOTOCONTROL WILL NEED
TO BE INSTALLED. SEE STEP 1 BELOW.
TO BE INSTALLED. SEE STEP 1 BELOW.
- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT WILL
- IF “PC” WAS SPECIFIED WHEN ORDERING, THE UNIT WILL
COME WITH THE PHOTOCONTROL INSTALLED. SEE STEP 4
COME WITH THE PHOTOCONTROL INSTALLED. SEE STEP 4
BELOW.
BELOW.
- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD WITH
- IF “NR” WAS SPECIFIED, THE UNIT COMES STANDARD WITH
A SHORTING CAP AND THE STEPS BELOW ARE NOT
A SHORTING CAP AND THE STEPS BELOW ARE NOT
NECESSARY.
NECESSARY.
1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF
1. REMOVE THE CUPOLA CAP BY GRABBING ONE SIDE OF
IT AND LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS
IT AND LIFTING UP. (SEE FIGURE 1) THE CUPOLA CAP IS
VERY RIGID AND TIGHT, DESIGNED SO IT DOESN’T EASILY
VERY RIGID AND TIGHT, DESIGNED SO IT DOESN’T EASILY
COME OFF. HOWEVER, IT MAY BE REMOVED BY HAND.
COME OFF. HOWEVER, IT MAY BE REMOVED BY HAND.
2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.
2. INSERT THE PHOTOCONTROL INTO THE RECEPTACLE.
3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH
3. REATTACH THE CUPOLA CAP. IT SHOULD REATTACH WITH
A VERY AUDIBLE SNAP.
A VERY AUDIBLE SNAP.
4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY
4. TURN THE PHOTOCONTROL WINDOW TOWARD NORTH BY
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING
GRABBING THE CUPOLA BASE WITH BOTH HANDS, LIFTING
AND TURNING SIMULTANEOUSLY UNTIL THE CUPOLA
AND TURNING SIMULTANEOUSLY UNTIL THE CUPOLA
WINDOW IS FACING NORTH. THE CUPOLA BASE AND THE
WINDOW IS FACING NORTH. THE CUPOLA BASE AND THE
PHOTOCONTROL RECEPTACLE ARE KEYED SO THE
PHOTOCONTROL RECEPTACLE ARE KEYED SO THE
PHOTOCONTROL TURNS AS THE CUPOLA DOES.
PHOTOCONTROL TURNS AS THE CUPOLA DOES.
CAUTION
THE LADDER REST IS FOR COSMETIC
PURPOSES ONLY. IT IS NOT
INTENDED FOR USE AS AN ACTUAL
REST FOR A LADDER.
!
FIGURE 3
FIGURE 3
LADDER REST INSTALLATION
LADDER REST INSTALLATION
PIN
PIN
GENTLY KNOCK HERE
GENTLY KNOCK HERE
FOR INSTALLATION.
FOR INSTALLATION.
TM
THIS DEVICE COMPLIES WITH PART 18 THE FCC RULES BUT MAY
THIS DEVICE COMPLIES WITH PART 18 THE FCC RULES BUT MAY
CAUSE INTERFERENCE WITH CORDLESS AND CELL PHONE,
CAUSE INTERFERENCE WITH CORDLESS AND CELL PHONE,
RADIOS, TELEVISIONS AND OTHER ELECTRICAL DEVICES.
RADIOS, TELEVISIONS AND OTHER ELECTRICAL DEVICES.
TO CORRECT THE PROBLEM MOVE THE DEVICE AWAT FROM THE
TO CORRECT THE PROBLEM MOVE THE DEVICE AWAT FROM THE
LUMINARY OR PLUG INTO A DIFFERENT OUTLET.
LUMINARY OR PLUG INTO A DIFFERENT OUTLET.
THIS PRODUCT MAY CAUSE INTERFERENCE TO RADIO EQUIPMENT
THIS PRODUCT MAY CAUSE INTERFERENCE TO RADIO EQUIPMENT
AND SHOULD NOT BE INSTALLED NEAR MARITIME SAFETY
AND SHOULD NOT BE INSTALLED NEAR MARITIME SAFETY
COMMUNICATIONS EQUIPMENT OR OTHER CRITICAL NAVIGATION
COMMUNICATIONS EQUIPMENT OR OTHER CRITICAL NAVIGATION
OR COMMUNICATION EQUIPMENT OPERATING BETWEEN
OR COMMUNICATION EQUIPMENT OPERATING BETWEEN
0.45-30 MHz.
0.45-30 MHz.
NOTE:
NOTE:
5 YEAR LIMITED WARRANTY
5 YEAR LIMITED WARRANTY