2 how to commission the appliance, 1 current supply, How to commission the appliance – Beijer Electronics EPC X EN User Manual

Page 11: 1 current supply -1, 2how to commission the appliance

Advertising
background image

2-1

2

How to commission the appliance

© Elektronik-Systeme LAUER GmbH & Co. KG • Kelterstr. 59 • 72669 Unterensingen • Tel. 07022/9660-0 • Fax 07022/9660-103

1

2

230 VAC

230 VAC

0 V

24 V DC

+ 24 V

2

How to commission the appliance

2.1 Current supply

Caution!
The EPC X may only be operated when using an extra-low voltage
combined with a safe separation according to the regulation EN60950!
The control transformer must correspond to the regulation EN60742!
Please check the distribution supply according to the type plate.
When wiring the voltage supply, and the a.c. voltage, please observe the
information on the type plate.
Please check all cable connections before operating the appliance.
The connection to the 0V distribution voltage shows low impedance when
connected to the casket (the earth)!

1

Power supply 24 V

2

Grounding screw

The current supply is effected via a bipole connector (Phoenix MST BT
2.5/2-STF-5.08)

Build-up of supply

Advertising