3 technical data, 3technical data – Beijer Electronics EXTER T100 EN User Manual

Page 13

Advertising
background image

Technical Data

Beijer Electronics, MAEN774C

13

3

Technical Data

Parameter

EXTER T100

Front panel, W x H x D 302 x 228 x 6 mm
Mounting depth

58 mm (158 mm including clearance)

Front panel seal

IP 66

Rear panel seal

IP 20

Keyboard material/
Front panel

Touch screen: Polyester on glass, 1 million finger touch
operations. Overlay: Autotex F157 or F207 *.

Reverse side material

Powder-coated aluminum

Weight

2.1 kg

Serial port RS422/
RS485

25-pin D-sub contact, chassis-mounted female with
standard locking screws 4-40 UNC.

Serial port RS232C

9-pin D-sub contact, male with standard locking screws 4-40
UNC.

Ethernet

Shielded RJ 45

USB

Host type A (USB 1.1), max output current 500mA
Device type B (USB 1.1)

CF-slot

Compact flash, type I and II

Flash memory for
application

12 MB (incl. fonts)

Real time clock

±20 PPM + error because of ambient temperature and supply
voltage. Total maximum error: 1 min/month at 25

°

C

Temperature coefficient: 0.004 ppm/

°

C

2

Real time clock
battery

CR2450 (UL and cUL: Sanyo or Panasonic)
Minimum lifetime: 3 years

Power consumption at
rated voltage

Normal: 0.5 A
Maximum: 1.0 A

Display

TFT-LCD. 800 x 600 pixels, 64K color.
CCFL backlight lifetime at the ambient temperature of
+25

°

C: >50,000 h.

Active area of display,
W x H

211.2 x 158.4 mm

Fuse

Internal DC fuse, 3.15 AT, 5 x 20 mm

Power supply

+24V DC (20 - 30V DC). Power supply connector.
CE: The power supply must conform with the requirements
according to IEC 60950 and IEC 61558-2-4.
UL and cUL: The power supply must conform with the
requirements for class II power supplies.

Ambient temperature

Vertical installation: 0

°

to +50

°

C

Horizontal installation: 0

°

to +40

°

C

Storage temperature

-20

°

to +70

°

C

Relative humidity

5 - 85 % non-condensed

CE approvals

Noise tested according to EN61000-6-4 emission and
EN61000-6-2 immunity.

UL, cUL approvals
(when procuct or
packing is marked)

UL 1604 Class I, Div 2 / UL 508 / UL 50 4x indoor use only

DNV

Yes

NEMA

4x indoor use only

* See section

Chemical Resistance

for more information.

Advertising