Beijer Electronics BFI-P2 v1.10 User Manual

Page 3

Advertising
background image

CANopen USER GUIDE

Beijer Electronics Automation AB

PAGE 3

CANopen specific Object table:

Table 5: Communication Profile Object Dictionary

Index

Sub

index

Function

Access

Type

PDO

Map

Default value

1000h

0

Device type

RO

Unsigned 32

N

0

1001h

0

Error register

RO

Unsigned 8

N

0

1002h

0

Manufacturer status register

RO

Unsigned 16

N

0

1005h

0

COB-ID Sync

RW

Unsigned 32

N

00000080h

1008h

0

Manufacturer device name

RO

String

N

ODP2

1009h

0

Manufacturer hardware version

RO

String

N

x.xx

100Ah

0

Manufacturer software version

RO

String

N

x.xx

100Ch

0

Guard time [1ms]

RW

Unsigned 16

N

0

100Dh

0

Life time factor

RW

Unsigned 8

N

0

1014h

0

COB-ID EMCY

RW

Unsigned 32

N

00000080h+Node ID

1015h

0

Inhibit time emergency [100us]

RW

Unsigned 16

N

0

1017h

0

Producer heart beat time [1ms]

RW

Unsigned 16

N

0

0

Identity object No. of entries

RO

Unsigned 8

N

4

1

Vendor ID

RO

Unsigned 32

N

0x0000031A

2

Product code

RO

Unsigned 32

N

Drive depended

3

Revision number

RO

Unsigned 32

N

x.xx

1018h

4

Serial number

RO

Unsigned 32

N

e.g. 1234/56/789

0

SDO parameter No. of entries

RO

Unsigned 8

N

2

1

COB-ID client -> server (RX)

RO

Unsigned 32

N

00000600h+Node ID

1200h

2

COB-ID server -> client (TX)

RO

Unsigned 32

N

00000580h+Node ID

0

RX PDO1 comms param No. of entries

RO

Unsigned 8

N

2

1

RX PDO1 COB-ID

RW

Unsigned 32

N

40000200h+Node ID

1400h

2

RX PDO1 transmission type

RW

Unsigned 8

N

254

0

RX PDO2 comms param No. of entries

RO

Unsigned 8

N

2

1

RX PDO2 COB-ID

RW

Unsigned 32

N

C0000300h+Node ID

1401h

2

RX PDO2 transmission type

RW

Unsigned 8

N

0

0

RX PDO1 mapping / No. of entries

RW

Unsigned 8

N

4

1

RX PDO1 1

st

mapped object

RW

Unsigned 32

N

20000010h

2

RX PDO1 2

nd

mapped object

RW

Unsigned 32

N

20010010h

3

RX PDO1 3

rd

mapped object

RW

Unsigned 32

N

20020010h

1600h

4

RX PDO1 4

th

mapped object

RW

Unsigned 32

N

20030010h

0

RX PDO2 mapping / No. of entries

RW

Unsigned 8

N

4

1

RX PDO2 1

st

mapped object

RW

Unsigned 32

N

00060010h

2

RX PDO2 2

nd

mapped object

RW

Unsigned 32

N

00060010h

3

RX PDO2 3

rd

mapped object

RW

Unsigned 32

N

00060010h

1601h

4

RX PDO2 4

th

mapped object

RW

Unsigned 32

N

00060010h

0

TX PDO1 comms param No. of entries

RO

Unsigned 8

N

3

1

TX PDO1 COB-ID

RW

Unsigned 32

N

40000180h+Node ID

2

TX PDO1 transmission type

RW

Unsigned 8

N

254

1800h

3

TX PDO1 Inhibit time [100us]

RW

Unsigned 16

N

0

0

TX PDO2 comms param No. of entries

RO

Unsigned 8

N

3

1

TX PDO2 COB-ID

RW

Unsigned 32

N

C0000280h+Node ID

2

TX PDO2 transmission type

RW

Unsigned 8

N

0

1801h

3

TX PDO2 Inhibit time [100us]

RW

Unsigned 16

N

0

0

TX PDO1 mapping / No. of entries

RW

Unsigned 8

N

4

1

TX PDO1 1

st

mapped object

RW

Unsigned 32

N

200A0010h

2

TX PDO1 2

nd

mapped object

RW

Unsigned 32

N

200B0010h

1A00h

3

TX PDO1 3

rd

mapped object

RW

Unsigned 32

N

200D0010h

Advertising