Restricting Free Expansion of the Panels
Recognize the need for oversized holes where pipes or conduits penetrate the wall. Failure to
oversize any necessary holes through the panel could force the FRP panel to buckle or bubble.

Avoid post installation additions, such as ceramic tile base directly over the FRP panel. Such
additions restrict expansion space of the panel. (Figure 10)

Properly Rolling or Pressing Entire Panel as it is Positioned
Use linoleum roller, J-roller or diligent hand pressure to adhere entire surface of the panel, ensuring
good contact over the entire panel.

Place panel against surface and press fi rmly over entire surface, working from the edge of the panel
where molding is installed outward to the open edge.

Adhesive needs to come in contact over the entire wall substrate. If not, the adhesive may not bond,
creating bubbles. (Figure 11)

Apply adhesive around panels where edges are exposed, around oversized holes for pipes or conduits
and along baseboard moldings where moisture can penetrate.

Use grommetted heads and adhesive where fasteners penetrate panel.

___________________________________________________________________________________________________________

Figure 11

Product Comparison Guide

Advanced Polymer

Fast Grab

Application

Recommendations

Porous and most non-porous substrates

Interior and exterior applications

Fiberglass faced, mold resistant and fi recode
core drywall, drywall, steel, foamboard, vinyl,
PVC, FRP,ceramic tile, laminate, sealed and
unsealed concrete

• Porous

substrates

Interior drywall applications

• Non-treated

plywood

Cure Process

Cures as moisture penetrates the adhesive (reactive)

Dries as water leaves adhesive

Open Time

20 minutes

20 minutes

Application

Temperature

50 - 90°F

50 - 90°F

Benefi ts

Easy to trowel

• Quick

grab

• VOC-compliant
• Nonfl ammable

Mold & mildew resistant

Fast strength development

Quick grab formula - requires minimal bracing

• VOC-compliant
• Nonfl ammable

No offensive odor

• Environmentally

safe

Easy to trowel

Coverage

Approximately 60 sq. ft. per gallon

Approximately 50 sq. ft. per gallon

Cleanup

It is important to clean-up adhesive immediately
while still wet. To clean adhesive from panel, tools
and hands while wet, use mineral spirits or isopropyl
alcohol and a rag. Once adhesive has cured, it can
be extremely diffi cult to remove. Follow solvent
vendor’s precautions. NOTE: Test solvent in an
out-of-the-way area to make sure it will not mar or
attack the surface.

Tools and excess adhesive may be cleaned with
water or isopropyl alcohol while wet. If adhesive has
dried, use mineral spirits. Follow solvent vendor’s
precautions when using solvents. NOTE: Test solvent
in an out-of-the-way area to make sure it will not mar
or attack the surface.

Specifi cations

Meets GreenSeal GS-36, LEED, SCAQMD, CARB,
NAHB Green Building specifi cations and NFPA Class
A fi re rated.

Meets GreenSeal GS-36, LEED, SCAQMD, CARB,
NAHB Green Building specifi cations and NFPA Class
A fi re rated. FDA and Canadian Food Inspection
Agency (CFIA) approved for indirect food contact.

Figure 10: Avoid post installation
additions

Advertising