FUNCTIONAL CHARACTERISTICS

2

2.1.1 Blocking the keypad

The keypad can be blocked by pressing the

+

and

-

buttons simultaneously and

holding them down for 5 seconds. The message “Lo” will appear on the display. This
message will then appear on the display when any button is pressed.

To unblock the keypad, press the

+

and

-

buttons again simultaneously and hold them

down for 5 seconds. When the message “Lo” disappears from the screen this means
the keypad has been unblocked.

2.2.1 Correcting the sensor temperature measurement

The appliance has an option for adjusting and correcting the temperature. As the ther-
mostat is located on the bottom of the appliance there may be a difference between
the temperature at the sensor level and the temperature at a height of 1½ metres. The
sensor may also be particularly affected by draughts, which can alter its measurement.

With this option, the radiator temperature can be adjusted to the temperature of a ther-
mometer located in any desired position.

To correct the sensor temperature, hold down the

-

and

buttons for 5 seconds

and then press the

+

/

-

buttons to change the temperature setting.

If the room temperature is lower than or the same as the temperature selected on the
display and the word “ON” does not appear in the top corner of the display, you should
reduce the sensor temperature until “ON” appears on the screen. The selection limits
are

+

/

-

4.5 ºC. The default confi guration is 0ºC.

To return to the initial display, press the

-

and

buttons twice, although if no buttons

are pressed it will automatically exit this mode after 120 seconds.

2.1 Switching on the appliance

To start up the Eco-heater, proceed as follows:

2.2 Confi guration

Switch on the ON/OFF electrical current master switch on the rear of the Eco-heater. The red
indicator light comes on to show that the appliance is in standby mode.

Press the On/Standby button

to start up the radiator. When you switch off the radiator

using this button, two horizontal dashes will appear on the display “- -

Press the

button to choose between the different functioning modes: comfort mode

, economy mode

or anti-frost mode

and programming mode (model IP only).

- Comfort mode

: You may select the desired temperature (increasing it by 0.5ºC at a

time) by pressing the

+

and

-

buttons. The selection limits are 7ºC and 30ºC.

- Economy mode : Ideal for use at night when the home is occupied, and during the dayti-

me when the house is empty. It is automatically set at a temperature 3.5ºC lower than the
setting selected for comfort mode.

- Anti-frost mode

: Ideal for empty homes. The temperature is set to 7ºC.

- Programming mode: the following option is for model IP only and is explained in section 3

of the manual.

Press the

+

/

-

buttons to select the desired temperature. Only the comfort mode

tempe-

rature can be selected, as the economy mode

temperature is automatically set 3.5ºC lower

than the comfort mode temperature, and the anti-frost mode

temperature is a set value.

a