Occupational exposure limits

Ingredient

CAS Nbr

Agency

Limit type

Additional comments

Formaldehyde

50-00-0

Health and
Safety Comm.
(UK)

TWA:2.5 mg/m3(2
ppm);STEL:2.5 mg/m3(2 ppm)

Propan-2-ol

67-63-0

Health and
Safety Comm.
(UK)

TWA:999 mg/m³(400
ppm);STEL:1250 mg/m³(500
ppm)

Health and Safety Comm. (UK) : UK Health and Safety Commission
TWA: Time-Weighted-Average
STEL: Short Term Exposure Limit
ppm: parts per million
mg/m³: milligrams per cubic metre
CEIL: Ceiling

8.2. Exposure controls

8.2.1. Engineering controls
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure
Limits and/or control dust/fume/gas/mist/vapours/spray. If ventilation is not adequate, use respiratory protection equipment.

8.2.2. Personal protective equipment (PPE)

Eye/face protection

The following eye protection(s) are recommended: Safety glasses with side shields.

Skin/hand protection

Skin protection is not required. Select and use gloves and/or protective clothing to prevent skin contact based on the results
of an exposure assessment. Consult with your glove and/or protective clothing manufacturer for selection of appropriate
compatible materials.

Respiratory protection

Select one of the following approved respirators based on airborne concentration of contaminants and in accordance with
regulations:
Half facepiece or fullface air-purifying respirator with organic vapour cartridges and P2 particulate prefilters.

SECTION 9: Physical and chemical properties

9.1. Information on basic physical and chemical properties

Physical state

Liquid.

Appearance/Odour

Clean, fresh odour; Clear liquid

pH

9 - 9.9

Boiling point/boiling range

>= 82.2 ºC

Melting point

Not applicable.

Flammability (solid, gas)

Not available.

Explosive properties

Not determined.

Oxidising properties

Not determined.

Flash point

> 93.3 ºC [Test Method:Pensky-Martens Closed Cup]

Flammable Limits(LEL)

No data available.

Flammable Limits(UEL)

No data available.