NDSP:

Inverted Digital readout - used while unit is mounted on truss or ceiling.

(if you are going to be looking at the LCD display while unit is hanging down – it is
recommended that you invert the LCD screen read out so you can look at it normal)

TALL:

Test all channels of unit. If you want to test all channels. Press Enter.

(LCD changes to read –

CH01

– press Enter. Channel 1 (lamp and fan channel) will

start to come up in brightness and the fans will increase in speed to cool fixture.
Press Black UP button. LCD changes to

CH02

. Press Enter. Lamp will start to flash and

strobe.
Press Black UP button. LCD changes to

CH03

. Press Enter. Fixture will run through it

full PAN capability.
Press Black UP button. LCD changes to

CH04

. Press Enter. Fixture will run through its

full TILT cycle.
Press Black UP button. LCD changes to

CH05

. Press Enter. Does fine adjust – PAN.

Press Black UP button. LCD changes to

CH06

. Press Enter. Does fine adjust – TILT.

Press M/C Black button to exit this test mode.

TLMP:

Time of usage on lamp. Press Enter. Fixture will start to come up and fans will increase
in speed for maximum cooling

RSET:

Unit resets itself to factory settings. TEST

Press Enter

DEMO:

Unit runs it programs in a demo mode. 3 options: O

OFF – Fixture to be controlled by lighting controller

SLAV – subordinate – daisy chained – inline with controller

AUTO – runs automatically

Press Enter

TEST:

Specific channel you wish to test.

Press Enter.

Y DIR:

Set either clockwise or counterclockwise response. Individual channel test runs
a full range of the Tilt Function (“Y” reverse) – Mirror image if need be.

Press Enter.

X DIR:

Set either clockwise or counterclockwise. Individual channel test runs a full
range of the Pan Function (“X” reverse). Mirror image if need be.

Press Enter.

NDST

DISP

TALL

LAMP

NDST

DISP

TALL

LAMP

LAMP INSTALLATION:

Replacing or installing the lamp.

-

Disconnect Power from fixture. If lamp is broken, make sure no pieces of glass are rattling around
inside.

-

On the back of the unit. Locate two (2) Spring clips. Push forward – the back will hinge open.

-

Remove 8” retaining ring.

-

Carefully insert Par 64 lamp of choice into / onto 4 long Teflon holders.

-

Push lamp forward enough to the front brace.

-

Position retaining clip back around the lamp to hold in place.

-

Carefully plug the Ceramic lamp socket onto lamp. As far as it can.

Note:

If not seated correctly, this could cause the socket to come loose from the lamp.

-

Hold Back the two spring loaded clips and shut back of unit. Lock in place.

-

Move unit head up and down to hear if there is any noise. If no noise, it is correctly seated.