Lighting instructions, Smb 600 series -ce models with safety pilot – Magikitch'n FM User Manual

Page 19

Advertising
background image

1. LIGHTING INSTRUCTIONS


SMB 600 Series -CE Models with safety pilot

1. Turn all burners to OFF.
2. Remove the top grid.
3. Turn the shut off valve to ON.
4. Press and hold the reset (blue) button on the safety pilot valve. Wait 15–30 seconds. Light the runner tube.

DO NOT release the reset button.
NOTE: If the runner tube does not light, wait a few seconds, then try again.

NOTE: When lighting the runner tube for the first time after connecting the unit to the gas source, the light time

will probably increase to 1–2 minutes.

5. Wait an additional 15–30 seconds. Release the reset button. The runner tube should remain lit.

NOTE: If the runner tube fails to ignite, repeat step 5. If the runner tube fails to ignite after three attempts,

contact an authorized MagiKitch’n service agent.

5. Replace the top grid.
6. Push and turn the burner valves to operate the individual burners as needed.



Broiler Shut Down
1. Turn the shut off valve to OFF.

2.

Turn all burners to OFF.

31-01-12962 rev B L25-004 rev

1 (05/11)

15

Advertising
This manual is related to the following products:

CM, APM, APL