Pneumatic Diaphragm Valves (NC)

D. Indicating Switch Option Installation

1. IS option for AK/AP/AZ3000, AP3113, AP3130, or AK/AP/AZ3200:

a.

Review the following specifications to verify the switch is appropriate for the installation.

Switch model

OKI Sensor ORT551

Switch type

SPDT

Operating temperature

-40 to 80 C

Supply voltage

30 VDC max.

Power

3 VA max.

Switching current

0.2 A max.

Carrying current

0.5 A max.

Life expectancy

Up to 5,000,000 cycles at 1.2 VA

Connectors

Stranded 24 AWG wire (blue, black, and
brown leads), 10 ft (3 m) long

b.

Connect blue lead to common output.

c.

Connect brown lead to normally closed input (the circuit will be closed when valve is
closed).

d.

Connect black lead to normally open input (the circuit will be closed when valve is open).

2. ISO and ISC option for AK/AP/AZ3550, AK/AP/AZ4550, or AP3700:

a.

Review the following specifications to verify the switch is appropriate for the installation.

ISO switch model

Alcoswitch MSPM101C104

ISC switch model

Alcoswitch MSPM101B104

Switch type

SPST

Operating temperature

-10 to 80 C

Supply voltage

50 VDC max.

Supply current

100 mA max.

Power

1.0 VA optimum

Initial contact resistance

100 milliohm max.

Life expectancy

up to 5,000,000 cycles at 0.1 VA

Connectors

Lug terminals – can be soldered or will accept
.110 quick disconnect receptacles

b.

Connect common input to one lug terminal (solder wire or use .110 quick disconnect
receptacle).

c.

Connect signal input to other lug terminal (solder wire or use .110 quick disconnect
receptacle). For ISO option, the circuit will be closed when the valve is open. For ISC, the
circuit will be closed when the valve is closed.