APTech AP 4650 User Manual

APTech Control panel

Advertising
background image

APTech Miscellaneous Instructions

#123650C0

AP3650, Panel Mount
Revision 2
February 5, 2013

Page 1 of 2

123650C0.doc

* A printed copy of this document is uncontrolled unless it shows a CONTROLLED COPY stamp in red. *

Note: This procedure is intended for panel mount of AP/AZ/AK/3650/4650 Series valves.

2

Note: Recommended panel hole diameter: 0.78 inch (19.8 mm).

A. Required Tools and Equipment
• Size 2 Phillips bit and 20 in·lbf (2.3 Nm) torque wrench. Optionally a size 2 Phillips screwdriver

may be used if an appropriate torque wrench cannot be obtained.

• 5/64 inch hex bit and 20 in·lbf (2.3 Nm) torque wrench. Optionally a 5/64 inch hex key may be

used if an appropriate torque wrench cannot be obtained.

• 1 inch wrench (open end or adjustable).

• Adhesive removal (optional).

B. Knob Removal (Refer to Figure 1)

1.

Remove the valve from the double plastic bag.

2.

Remove the label (#1) from the top of the knob (#2).

3.

Using a Phillips screwdriver, unscrew and remove the screw (#3) and finishing washer (#4).

4.

Close the valve by turning the knob fully clockwise.
Note: Remember the orientation of the knob window in the “closed” position so that it may be
re-oriented in the same position during re-assembly.

5.

Lift up the knob to remove it from the valve.

6.

Use a 5/64 inch hex key to loosen the two set screws (#5) a couple of turns.

7.

Lift up the indicator plate (#6) to remove it from the valve.

C. Panel Mount (Refer to Figure 1)

1.

Remove the panel mount nut (#7) from the unit.

2.

Place the valve through the panel hole, position the valve as desired, connect the valve into piping
system and replace the panel mount nut onto the unit.

3.

Using a 1 inch wrench, tighten the panel mount nut firmly against the panel.

D. Knob Replacement (Refer to Figure 1)

1.

With printed words facing up place the indicator plate (#6) on top of the cap (#8). Rotate the
indicator plate so that the quarter-circular slot on the top of it is facing the desired “closed”
location of the knob window.

2.

Holding the knob (#2) just above the stem (#9), orient the knob window to the desired “closed”
position, and then slide the knob down to engage the spline connection with the stem.

3.

Rotate the indicator plate counter-clockwise until it stops.
Note: the word “CLOSED” should be fully visible through the knob window.

4.

Holding the indicator plate down, tighten the two set screws (#5) to 20 in·lbf (2.3 Nm) using a
5/64 inch hex bit.

5.

Secure the knob with the finishing washer and the screw, tightening it to 20 in·lbf (2.3 Nm) using
a Phillips bit.

E. Valve Testing

1.

Open and close the valve several times to verify the actuator operates correctly. The valve
actuator should have no excessive friction. Leave the valve in the closed position.