4 Absolute Ratings of Environment

Item

Symbol

Min.

Max.

Unit

Note

Storage temparature

T

STG

-25 60

°C (1)

Operating temparature

(Glass surface temperature)

T

OPR

0 50

°C (1)

Shock (non-operating)

Snop

-

50

G

(2), (4)

Vibration (non-operating)

Vnop

-

1.5

G

(3), (4)


Note
(1) Temperature and relative humidity range are shown in the figure below.

90 % RH Max. (40

°C

≥ Ta)

Maximum wet-bulb temperature at 39

°C or less. (Ta > 40 °C) No condensation.

(2) 11 ms, sine wave, one time for

±X, ±Y, ±Z axis

(3) 10-300 Hz, Sweep rate 10 min, 30 min for X, Y, Z axis
(4) At vibration and shock test, the fixture which holds the module to be tested has to be hard and rigid enough so

that the module would not be twisted or bent by the fixture.