INSTALLATION INSTRUCTIONS

Your air conditioner is designed to install in standard double hung windows with opening widths of

22 to 36 inches(559mm to 914mm) (See Fig.1).

Lower sash must open sufficiently to allow a clear vertical

opening of 14-1/2 inches (368mm). Side louvers and the rear

of the AC must have clear air space to allow enough airflow

through the condenser, for heat removal. The rear of the unit

must be outdoors, not inside a building or garage.

Fig.1

NOTE: Save Carton and these Installation Instructions

for future reference. The carton is the best way to store unit

during winter, or when not in use.

3 4 Screws

(7)

Lock Frame

(2)

Sash Lock

(1)

Mounting Hardware

TOOLS NEEDED:

Phillips Screw Driver

Drill(If pilot holes are needed)

CAUTION: When handling unit, be careful to avoid cuts from

sharp metal edges and aluminum fins on front and rear coils.

Top Rail Hardware

3 8 Screws

(4)

Top Rail

(1)

Before installing unit, the top rail must be assembled

on the unit.

Tool Needed: Phillips Screwdriver

A: Remove the air conditioner from the carton and place

on a flat surface.

B: Remove top rail from the bottom of the packaging

material as shown in Fig.A

7

C: Align the hole in the top rail with those in the

top of the unit as shown in Fig.B

Fig.B

Fig.C

D: Secure the top rail to the unit with the 3/8

Screws as shown in Fig.C.

NOTE: For safety reasons, all four(4) screws

MUST be securely fastened.

,,

OFFSET

EXTERIOR

WALL

STOOL

SILL

INTERIOR

WALL

22 to 36

559mm to 914mm

14 1 4 min.

/

(337 mm)