Operating specifications, Mechanical specifications – RMS Technologies IMDE17 INTEGRATED MOTOR + DRIVER + ENCODER User Manual

Page 7

Advertising
background image

RMS Technologies

Page 7

Version 1.04

IMD17/IMDE17

10/1/2007

3. OPERATING SPECIFICATIONS

Operating Temperature:

-20° to 50° Celsius

Humidity Range:

0 to 95% (non-condensing)

100% duty cycle is OK as long as bottom of unit is 50°C or less (bottom of unit is

where the black heat sink fins are located)


Logic Input Timing

(A) Minimum Command Active Time

Before Step Pulse (Data Set-up Time)

200 nanoseconds

(B) Minimum Command Active Time

After Step Pulse (Data Hold Time)

200 nanoseconds

(C) Minimum Step Pulse Width

20

microseconds

(D) Minimum Step Low Time

20

microseconds

(E) Maximum Power-Down Recovery Time

20 milliseconds

Maximum

Step

Frequency

25

kHz

Figure 1: Timing Diagram

4. MECHANICAL SPECIFICATIONS

A.

Motor Front Shaft Extension Length

Standard length is 0.94”. Customized length is available.

B.

Motor Shaft Diameter

Standard shaft diameter is 0.1968”. Customized diameter length is also
available.

C.

Overall Body Length

Motor body length is available in various lengths

IMD17-S05 (2.69”)
IMD17-M04 (2.92”)
IMD17-L04 (3.24”)

Advertising
This manual is related to the following products: