Configuring the settings, Onnect to, River – RMS Technologies IMDP 23 W/ POLE DAMPING TECHNOLOGY*NEW* User Manual

Page 16: For setting, Arameters

Advertising
background image

RMS Technologies

Page 16

Version 1.04

IMDP23/IMDEP23 Manual

8/4/2010

7

Configuring The Settings


Connect to RMS Driver GUI for setting Parameters

Download the RMSDriver.zip file from the IMDP23 webpage.

Connect to your PC, and turn on the Power Supply.

Figure 19: GUI






Setting

Values

Description

Full step, 2x, 4x,
5x, 8x, 10x, 16x,
25x, 32x, 50x, 64x,
125x, 128x, 250x,
or 256x.

MicroStep: Changes the step resolution such
that the motor will step in smaller increments.
This helps with smooth and quiet operation.

0 to 6350 msec, in
50 msec
increments

1000 msec = 1 sec

Hold current delay time: This setting is a time
delay in milliseconds. After the last step pulse
is sent to the motor, there will be a delay time
for when the motor switches from run to hold
current. This can be beneficial if moving a
large load that needs high current during 1 or
2 seconds after a move is completed, but
beyond this, you may want to hold the unit
using less power.

Select the COM port

and click “Connect”

1

2

3

Make changes to
current,
microstepping,
etc.

Click “Program”
to store the

settings.