FEATURES

NEMA Size 23, 2 Phase, 1.8° Bipolar Step Motor w/ Built-In Microstepping Driver

Operates from +12 to 75 VDC

Software selectable run currents from 0.1 to 5.0 Amp Peak (in 0.05 Amp increments)

Software selectable hold currents from 0 to 5.0 Amp Peak (in 0.05 Amp increments)

Step Resolutions from Full step, 2x, 4x, 5x, 8x, 10x, 16x, 25x, 32x, 50x, 64x, 125x,
128x, 250x, 256x Microstepping

Four Selectable Damping modes for smooth motion

No low minimum inductance (any NEMA 23, 1.8° step motor can be selected)

Step sensing on the rising or falling edge of step pulse input

Direction switching – to change first powered on direction of rotation

Enable active high or low – to allow unit to be enabled with a high or low signal

Smooth motion

Three optically isolated control inputs (step, direction, disable)

Inputs are sinking inputs, maximum current input is 15mAmps

Pole Damping Technology™ integrated within driver board


Pole Damping Technology™

Pole Damping Technology™ (PDT) enhances step motor performance by dampening each
full step in order to create a more accurate and smooth motion profile. Microstepping the
step motor will optimize Pole Damping Technology™. PDT outputs the correct amount of
run and hold currents to the motor, at the right time. Thus, it will overcome the step
motor’s natural tendency to want to forcefully pull towards the full step ON position.

IMDEP23 – Encoder Features

32-1250 cycles per revolution (CPR)

128 to 5000 pulses per revolution (PPR)

2 Channel Quadrature

TTL Squarewave Outputs and optional index (3

rd

Channel)

E2 US Digital Encoder


Default Settings

Default Settings of the IMDP23 or IMDEP23

Direction of rotation

Counterclockwise

Step Resolution

8x step (3200 steps/rev)

Run Current

Motor’s rated current or up to
5 Amps Peak if motor is rated
for 5 or higher.

Holding Current

0.5 Amp/Phase

Smoothness setting

2

Step signal sensing

Senses on the Rising Edge or
positive edge

Disable Active

Low or 0V signal to disable
unit

Table 1: Default settings