8. COMMAND TABLES



Axis Configuration Commands

Function

Query/New Code Value

Minimum

Maximum

Default

Hold Timeout

Q/N

HT

Numeric 100

5000

5000

Percent Fast

Decay

Q/N PF

Numeric

0

3

2


General Operation Commands

Function

Query/New Code Value

Minimum

Maximum

Default

Firmware Rev.

Q

FR

Numeric -

-

-

Communicating with the R325

1. Place a jumper on pins 7 and 8 of JP1.

2. Communicate via RS485 with P3.


3. Set up HyperTerminal by selecting correct COM port

4. Settings for HyperTerminal is as follows: 57600, 8 bits, None, 1, None

2. The R325 Driver only version allows for changing the hold timeout settings,

the amount of mixed decay, and to check the firmware revision level.