I n S t A l l A t I o n

The oven must be mounted on the factory equipped

oven legs or on an optional oven stand. Installation

on a solid or concrete base that in any way restricts

air flow may void the warranty.

All clearances for a proper ventilation air supply

must be maintained to minimize fire hazard. Do not

locate the oven immediately adjacent to any other

heat-generating appliance.

A number of adjustments are associated with

initial installation and start-up. Adjustments

must be conducted by a qualified service

technician. Installation and start-up adjustments

are the responsibility of the dealer or user.

These adjustments include but are not limited

to thermostat calibration, door adjustment, and

leveling. The Platinum series oven burners are

factory-adjusted with fixed air openings and require
no field adjustment.

lEvElInG

The oven should be leveled before

the gas supply is connected. level the oven from

side-to-side and front-to-back with the use of a

spirit level. For ovens installed on a mobile stand,

it is important that the floor surface be level due to

the probability of frequent oven repositioning.

We recommend checking the level of the oven

periodically to make certain the floor has not

shifted nor the oven moved.

I N S T a l l a T I O N R E Q u I R E M E N T S

d A n G E R

IMPROPER INSTALLATION,
ALTERATION, ADJUSTMENT,
SERVICE, OR MAINTENANCE COULD
RESULT IN SEVERE INJURY, DEATH,
OR CAUSE PROPERTY DAMAGE.
READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR SERVICING
THIS EQUIPMENT.

C A U t I o n

TO PREVENT PERSONAL INJURY,

USE CAUTION WHEN MOVING OR

LEVELING THIS APPLIANCE.

RESTRAINT REQUIREMENTS
—MOBILE EQUIPMENT

Any appliance that is not furnished with a power

supply cord but includes a set of casters must be

provided with a tether. Adequate means must be

provided to limit the movement of this appliance

without depending on or transmitting stress to the

electrical conduit. The following requirements apply:

1.

Casters must be a maximum height of 6" (152mm).

2.

Two of the casters must of be the locking type.

3.

Such mobile appliances or appliances on mobile

stands must be installed with the use of a flexible

connector secured to the building structure.

A mounting connector for a restraining device

is located on the lower back flange of the appliance

chassis or on an oven stand, approximately

18" (457mm) from the floor. A flexible connector

is not supplied or available from the factory.

w A R n I n G

RISk Of ElEcTRIc ShOck.

Appliance must be secured

to building structure.

Where automatically operated appliances are vented through a ventilating hood or

exhaust system equipped with a damper or with a power means of exhaust, provisions

shall be made to allow the equipment to operate only when the damper is open to a

position to properly vent the appliance and when the power means of exhaust is in

operation.