Rp 204628 1k2582_3028_5.pdf, Safety instructions, Warnings – Aprilaire 8100 User Manual

Page 14: System start-up

Advertising
background image

–3–

SAFETY INSTRUCTIONS

Read the Safety and Installation Instructions carefully. They will help insure a correct and
SAFE installation of the Aprilaire

®

Energy Recovery Ventilator.

WARNINGS:

1. 120 Volts may cause serious injury from electrical shock. Sudden operation may cause serious injury

from moving parts. Leave power disconnected until installation is completed.

2. The fresh air intake

must be

mounted in a location removed from sources of dangerous toxic gases.

Examples of such sources, but not limited to these sources, include the exhausts from condensing
furnaces, condensing water heaters and vented space heaters. These exhausts contain toxic
substances that can be harmful to humans.

The fresh air

intake

should be installed a minimum of 10 feet from any exhaust vent.

3. Connection with existing air exhaust sources may cause toxic conditions in the living area. The

Aprilaire ducting must be separate from sources such as dryer vents, water heater, furnace flues,
gas appliance flues or bathroom and kitchen exhausts.

4. Unit weight and dropping may cause personal injury or equipment damage. Handle with care and

follow installation instructions.

5. WARNING: To avoid serious injury, do not mount unit with access door facing down.

Unit must be mounted in an upright position.

6. Sharp edges may cause serious injury from cuts. Wear protective gloves and handle with care.

7. Excess negative or positive pressure may cause health problems or structural damage. Air flow

must

be balanced after installation.

8. Insufficient combustion air may cause toxic conditions. The Energy Recovery Ventilator

must not

exhaust air from an enclosed room with combustion appliances.

9. Installation

must

conform to all applicable codes.

10. The fresh air duct from outside the Energy Recovery Ventilator and the stale air duct from the

Energy Recovery Ventilator to the outside

must

be fully insulated. The fresh air duct connection

to the unit

must

also be completely insulated. This is to prevent condensation from forming on

the ductwork.

NOTE: This manual does not express or imply any warranty conditions. See Owner’s Manual for further information.

–14–

• All the same mounting, locating, ducting and electrical

hook-up guidelines apply for retrofitting as they do in
new home installations.

5. Fasten door securely to housing.

6. Place all dampers in “full open” position.

7. Balance the system air flows per instructions on

page 15.

8. Give owner’s manual and warranty card to homeowner

after explaining operation of unit.

INSTALLATION INTO EXISTING HOME (RETROFITTING)

INSTALLATION IN HOMES WITHOUT FORCED AIR

(HYDRONIC OR ELECTRIC BASEBOARD)

All the same mounting, locating, ducting and electrical
connection procedures apply to this situation as they do
in new home construction, except for the following
changes:

• The Aprilaire Energy Recovery Ventilator can be properly

installed into a home with no forced air ducts by
installing fresh air supply ducts to various parts of the
house where fresh air is needed.

• It is recommended that no more than 3 fresh air supply

ducts be used to assure an adequate air flow.

The total free Area of supply grilles should not be less
than 75 square inches. Use of less than the minimum
free area may result in greater than the normal air
movement noise.

• Three (3) supply ducts require a minimum of 25 square

inches free area each. Two (2) supply ducts require a
minimum of 40 square inches free area each. One (1)
supply duct requires a minimum of 75 square inches
free area.

Do not place a supply outlet in the same room or in the

vicinity of the stale air return from the house.

• Try to place the supply of fresh air to the house outlet,

or outlets, in a hall or foyer to avoid drafts and possible
blower noise in occupied areas.

• Try to keep all supply duct runs short, straight and

equal in length.

SYSTEM START-UP

1. Make sure the EnergyMax Transfer Core and filters

are installed correctly.

2. Double check all ductwork connections to be sure they

are installed and sealed properly.

3. Check to be sure all tools are removed from interior and

exterior of housing.

4. Make sure the blower motor and duct connections are

not obstructed.