4 – Troubleshooting

4.1 – Checking the Network Connections

CobraNet network connections can be diagnosed by noting the status of the LEDs just above the Ethernet connectors on
the CobraNet I/F port. These LEDs will be on, off, or flashing depending on the current state of the network
connection. Below is a table showing the states of the LEDs and what device status they represent.

LED status

Device Status

Left LED on permanently

Right LED off

No Ethernet Connection

Left LED on permanently

Right LED on but flashes off every 4 seconds

Ethernet connected but no devices found

Left LED on permanently

Right LED flashing 3 times a second

Connected and CobraNet devices found

Device is a performer

Left LED on flashing 3 times a second

Right LED flashing 3 times a second

Connected and CobraNet devices found

Device is the conductor

Table 1 - CobraNet Interface LED Status


4.2 – Common Faults

Below are some common faults. Accompanying each one is a list of the most common solutions. While the lists of
solutions are not exhaustive, they represent the majority of the likely failures.

No devices show up in Control Center

o

Ensure the PC is running Windows 98SE or later (Windows 95 is not suitable)

o

If running Vista, ensure a Vista compatible version of Control Center is running (1.4.0 onwards)

o

Check the PC is connected to the same Ethernet infrastructure the CobraNet is running on

o

Check a network card has been selected for Control Center to use and if the PC has multiple cards, check it’s
the correct one

o

Ensure the network card being used by Control Center has its IP address configured correctly

o

Check the switches used to interconnect devices are powered up

o

Check the CobraNet nodes on the network are powered up and running

o

Check firewall and Internet security settings to ensure CobraNet traffic can pass through unabated. These
may need to be disabled for Control Center to work

o

If the network switches are using a VLAN configuration, check the VLAN configuration is correct

o

Check the correct cabling has been used for each connection and they have been terminated properly



The DialogBox does not show up in Control Center

o

Check the DialogBox has power supplied to it and is turned on. Check the power light on the front

o

Check the Ethernet cable is correctly connected to an active network I/O port on the switch

o

If using a switch, ensure the Ethernet cabling is a standard patch cable and not a crossover type

o

If the PC is wired direct to the DialogBox, make sure a crossover cable is used



The DialogBox appears but its icon never turns green

o

Check the DialogBox has a valid IP address

o

Check IP address on the PC and the device to ensure they are within range of one another