ConTech Lighting CGL12 User Manual

Page 2

Advertising
background image

For Con-Tech Lighting 12" LED Decorative Pendant Series: CGL12

CGL12 INST

www.contechlighting.com

All specifications subject to change without notice.

1-847-559-5500

This document can be recycled.

2

4

CANOPY INSTALLATION:

Prior to installation, ensure a 4" Round or Square (with a Round-to-

Square Junction Box Cover Plate) Junction Box is properly

mounted to the ceiling structure
Loosen the two (2) side screws on the canopy (Figure 4), unhook

safety chain and remove mounting bracket from the canopy.

Attach the mounting bracket to junction box.
Position canopy and pendant assembly close to mounting bracket

and reconnect safety chain.

ELECTRICAL CONNECTION:

Connect the primary leads from the junction box to the primary

leads of the fixture (Black-to-Black, White-to-White and Green-to-

Ground). (Figure 4)
Carefully tuck excess wires and connectors in Junction Box while

positioning the canopy in place. Twist and lock canopy and tighten

side screws to complete assembly.

IMPORTANT SAFETY INSTRUCTIONS:

• Read all the instructions before installation. Save instructions for

later use.

• Turn off power at fuse or circuit breaker box before installation

of before doing any maintenance work.

• Wear rubber soled shoes and work should be done on a sturdy

wooden or non-conductive ladder.

• Product must be mounted in locations and at heights in a manner

consistent with its intended use, and in compliance with National

Electrical Code and local building codes. For indoor use only.

• Product must be grounded to avoid potential electric shock and

any other potential hazards.

• Do not exceed the nominal supply voltage or amperage ratings.

• Make sure all screws are properly tightened.

• Do not install any lamp holder closer than 6" from any curtain or

similar combustible material.

• Use only fixtures and fittings intended for use with Con-Tech

Decorative Stemlight Pendant systems.

• Installing contrary to instructions may cause unsafe conditions.

• Warning: Risk of fire. Most dwellings built before 1985 have supply

wire rated at 60˚C. Consult a qualified electrician before installation.

• Warning: Risk of burns. Lamps are extremely hot when lit. Allow

lamps to cool down in temperature before handling.

• To avoid hazards to children, account for all parts and properly

dispose of all packing materials.

• Call the Technical Support department at Con-Tech Lighting with

any installation questions: 847-559-5500.

White

to

White

Black to Black

Green to Green

(Ground Wire)

Black

Green

Green

White

White

Black

Black

Green

Green

Red

18-3 Cable

Strain Relief

Bracket

Junction Box

Ceiling

Mounting Bar

Driver

Canopy

(2) Side Screws

Advertising