Anton/Bauer DIONIC 90 User Manual

Page 11

Advertising
background image

9

RealTime Display Indications

• When the DIONIC battery is being charged remaining runtime is

not displayed.

• Remaining run time is calculated using the present available battery

capacity and a constantly updated accurate measurement of the
present load on the battery.

• If no load is detected, or if the battery is removed from the charger

before any discharge load is applied, the default assumed power for
remaining run time calculations is 20 Watts.


• When the battery determines that a load is attached, remaining run

time will be calculated based on that load and the time remaining
will be updated.

• The battery will “learn” this new load and retain that load

information in non-volatile memory. If the battery is removed from
the camera it will retain this information for 30 minutes or until it is
returned to the charger or sees a new load. After 30 minutes the
battery will return to the default load of 20 watts.

OVERCURRENT INDICATION

If the DIONIC 90 battery is

subjected to a load that exceeds specifications, the protection
electronics will operate to protect the lithium ion cells. All status
icons on the LCD will flash at a once per second rate.
This can
occur, for example, if a cold halogen light =/>75 watts is turned on.
When the over-load condition is removed, the display will return to
normal.

Advertising