5 the utility menu items, Figure 17: utility screen, N 8.1.5 – Kramer Electronics VP-747 User Manual

Page 40

Advertising
background image

VP-747 - Operating the VP-747

35

8.1.5

The Utility Menu Items

Figure 17: Utility Screen

Utility Screen Functions
Setting

Function

Default

TCP/IP

Setting

DHCP: Off or On

Off

IP Address

192.168.1.39

Subnet Mask

255.255.255.0

Gateway

192.168.1.254

Apply: Apply settings

OSD

Menu Position: Center, Top Left, Top Right, Bottom

Left or Bottom Right

Center

Time-Out: 5, 10, 20, 30, 60, 90 seconds or Off

30 Sec

Misc.

Settings

Logo: Off, On or Custom

ON for the start up Kramer logo to appear on the

screen;

OFF to disable the logo.

CUSTOM to select the downloaded

custom Logo

(Flash ROM)

Downloaded via USB (Logo Download)

On

Save Lock (see

Section 8.1.5.1

)

Input Lock: Off or On (see

Section 8.1.5.2

On

)

Background: Blue, Black or Disable Analog Sync

Black

Blank Color: Black or Blue

Event Mode: Off or On

If On is selected, the LCD displays “Invalid operation in the

event of pressing any program button”

Off

Baud Rate: 9600 or 115200

115200

Firmware Download: Download the firmware via the

USB connection, select the correct file from the

memory stick and Confirm

Do not press any buttons while the firmware is downloading

Logo Download: Download a new logo via the USB port

using a memory stick (see

Section 8.1.5.3

)

Advertising