Connecting Your SP-11D Digital Video Processor

11

6.2 DIP-Switch Settings

The SP-11D DIP-switch settings are defined in

Table 3

and

Table 4

:

Table 3: DIP-switch Settings

DIP-Switch

Set as follows:

1

Pedestal

ON for pedestal of output signal (7.5 IRE offset selection for NTSC); OFF for no

pedestal

2

HsVs/Cs1

ON for Composite Sync on outputs Hs/Cs and Vs/Cs; OFF for Horizontal Sync on

Hs/Cs, and Vertical Sync on Vs/Cs outputs

3

Secam VBI

ON for insert identification signals occupying 9 lines of field-blanking period (only for

SECAM output standard) (bottle pulses); OFF for no insert (no bottle pulses)

4, 5, 6 Test Signals The status of these DIP-switches defines the test signal: see

Table 4

7

AGC

ON for enabling automatic gain control; OFF for disabling automatic gain control

8

ADDR

For selecting one of two machine addresses (defining the machine address)

Table 4: Test Signals

FUNCTION

DIP 4 DIP 5 DIP 6

VITS 330 (Modulated Staircase) – full field mode

ON

ON

ON

No Signal

2

OFF

OFF

OFF

Split 75% Bar Generator

ON

ON

OFF

VITS 18 (Multiburst 5.8MHz) – full field mode

ON

OFF

ON

Vertical 75% Bar Generator

ON

OFF

OFF

Inverse Horizontal 75% Bar Generator

OFF

OFF

ON

Horizontal 75% Bar Generator

OFF

ON

OFF

VITS 17 (2T, 20T, 5 Step Staircase) – full field mode OFF

ON

ON

The example in

Figure 4

illustrates how to connect your SP-11D:

1 See the rear panel items 15 and 14 in

Figure 1

and

Table 2

2 This is the Main mode; test signals are not available

Advertising