Communication protocol – Kramer Electronics SP-11D User Manual

Page 20

Advertising
background image

KRAMER: SIMPLE CREATIVE TECHNOLOGY

Communication Protocol

18

GLOBAL

20

OUTPUT FORMAT

0 - YUV

1 - RGB

2 - RGBS

21

OUTPUT_STANDARD

0 - PAL B

1 - PAL N

2 - PAL M

3 - NT 3

4 - NT 4

5 - SEC

22

GENLOCK

0 - OFF

1 - ON

23

PANEL_LOCK

0 - OFF

1 – ON

24

SCH

-100 - +100

24

DELAY

-100 - +100

26

FREEZE

0 - OFF

1 - ON

27

PROGRAM

0 - 15 (read only)

28

GENLOCK_STAT

(Read only)

0 – No GENLOCK

1 – GENLOCK

Byte 4 is the machine address: can be 98 or 99 (in HEX).

First byte = I

Second byte=D

Third byte=E

MACHINE TO PC:

MACHINE POWER-UP

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

PRESS OF "RECALL"

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

PRESS OF "STORE"

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

CHANGE "OUTPUT_STANDARD"

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

CHANGING OTHER KEYS

PC <- I = 33;D = PARAMETER NUMBER; E = PARAMETER <- MACHINE (PARAMETER WRITE)

PC TO MACHINE:

RESET VIDEO

POWER-UP(PSEUDO)

PC -> I = 0;D = 0;E = 0 -> MACHINE

PC <- I = 0;D = 0;E = 0 <- MACHINE

DEFAULT

PC -> I = 0;D = 1;E = 0 -> MACHINE

WRITE EEPROM ALL PARAMETERS - DEFAULT (ALL PROGRAMS),RELOAD (RESTART)

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

PARAMETER READ

PC -> I = 32;D = PARAMETER NUMBER;E = 0 -> MACHINE

PC <- I = 32;D = PARAMETER NUMBER;E = PARAMETER <- PARAMETER

PARAMETER WRITE

PC -> I = 33;D = PARAMETER NUMBER;E = PARAMETER -> MACHINE

PC -< I = 33;D = PARAMETER NUMBER;E = PARAMETER <- MACHINE

WRITE OUTPUT_STANDARD

PC -> I = 33;D = 21;E = PARAMETER -> MACHINE MACHINE RELOAD (RESTART)

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE (RECALL)

RECALL

PC -> I = 34;D = 0;E = PROGRAMM NUMBER -> MACHINE

PC <- I = 34;D = 0;E = PROGRAMM NUMBER <- MACHINE

PROGRAMM NUMBER - 0 = PROGRAMM 1

PROGRAMM NUMBER - 1 = PROGRAMM 2

PROGRAMM NUMBER - 15 = PROGRAMM 16

Advertising